background image

English

CLASS

KLASSE

   

HDTV 1000 S

Head-End HDTV Converter to IP

DVB-S2 to SPTS 

GSS 

Grundig SAT Systems GmbH

Beuthener Strasse 43

D-90471 Nuremberg

Phone: 

+49 (0) 911 / 703 8877

Fax: 

+49 (0) 911 / 703 9210

E-mail: 

[email protected]

Internet: 

http://www.gss.de/en 

Summary of Contents for HDTV 1000 S

Page 1: ...SE HDTV 1000 S Head End HDTV Converter to IP DVB S2 to SPTS GSS Grundig SAT Systems GmbH Beuthener Strasse 43 D 90471 Nuremberg Phone 49 0 911 703 8877 Fax 49 0 911 703 9210 E mail info gss de Internet http www gss de en ...

Page 2: ... Virtual Station Tables 13 Programming via station tables 13 5 2 Programming procedure 14 5 3 Creating station tables 17 The structure of the text file for programming station tables 18 5 4 Uploading the station tables to the cassettes 22 5 5 Programming the cassette 23 Selecting the cassette 23 Selecting the station table 24 Setting the Ethernet parameters 24 Setting the hardware IP address of th...

Page 3: ...rd error correction 34 Setting the transmission channel 34 Setting the output data rate 35 Allocating services manually 36 Selecting the sound options of the service 37 Switching DVB service information on or off 37 Stuffing the output data rate 38 Displaying the output data rate 39 Factory reset 39 Saving settings 40 Operation with a CA module 41 Setting the PID monitoring 41 Configuring the CA m...

Page 4: ...its No liability is accepted for any damage caused by faulty connections or inappropriate handling Observe the relevant standards regulations and guidelines on the installa tion and operation of antenna systems The standards EN DINEN50083 and IEC EN DINEN60728 must be observed For further information please read the assembly instructions for the head end station used Test the software versions of ...

Page 5: ... EC The product fulfils the guidelines and standards for CE labelling page 45 Unless otherwise noted all values are specified as typical RF input Frequency range 925 2150 MHz Level range 60 dBμV 80 dBμV Return loss 8 dB DVB S modes QPSK 1 2 2 3 3 4 5 6 7 8 DVB S2 modes QPSK 1 2 3 5 2 3 3 4 4 5 5 6 8 9 9 10 8PSK 3 5 2 3 3 4 5 6 8 9 9 10 Symbol rate DVB S QPSK 2 45 MSymb s Symbol rate DVB S2 QPSK 10...

Page 6: ...uners The accompanying channel strips consist of the digital SAT tuners and the digital signal processing levels From the resulting data streams of the Tuner A and Tuner B channel strips up to 12 services can be taken and assigned with each an IP address Principle signal path TPS Tuner A Tuner B CA Modul CA module IP address Service 1 227 40 50 1 Service 2 227 40 50 2 Service 3 227 40 50 3 Service...

Page 7: ...ion of the control unit To operate this cassette the software version of the control unit must be V 44 or higher You can find the current operating software for the control unit and the cassette the software BE Flash and the current assembly instructions on the website www gss de en The cassette is intended for use in the STANDARD LINE head end stations 2 5 Software query Control unit If necessary...

Page 8: ...cket Remove the fastening screws 1 of an unoccupied slot from the bracket of the head end station Insert the cassette in this slot and push it into the housing Align the cassette and apply slight pressure to connect it to the connections of the board and the RF bus bar Fasten the cassette with the screws 1 CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CA...

Page 9: ...leading in and out for the 19 cabinet are made using cable terminals CLASS KLASSE The attenuation of shielding of the connection lines for ASI and antenna must meet the requirements for Class A Insert the required number of cable terminals in the openings provided in the head end station or in the 19 cabinet Tighten the nuts on the cable terminals until the teeth on the lock washer have penetrated...

Page 10: ...ind the current operating software on the website www gss de en 3 4 Connecting the cassette Connect the RF connections to the inputs 4 channel strip Tuner A and 2 channel strip Tuner B To connect a DiSEqC controlled multi switch 2 F jack to jack adapters cable connectors are attached The control voltage for a DiSEqC controlled multi switch which is present at the antenna input is not suitable as i...

Page 11: ...ambling several services The hardware and software of this cassette have been thoroughly prepared and tested Any changes made by service providers to the data structures in the service data might impair or even prevent this function When working with the CA module please read the corresponding operat ing manual from the respective provider Insert the smart card 1 into the CA module 2 so that the c...

Page 12: ... Programme tables optionally Setting Ethernet parameters Selecting the Input optionally Assignment of the IP addresses optionally Data Mode Displaying the data rate Factory reset depending on the activation of the virtual station tables 4 2 Control panel The key pad on the head end station is used to scroll through the menus scrolls forward through the menus select parameters in the menus set valu...

Page 13: ...iving cassettes as well as their assignment to the transmission channels transponders of the transmitting cassettes is done by a text file which must be uploaded to the cassettes The switchover of the different station tables is done via the menu LOCATION in the HDTV 1000 S cassettes This menu only appears if station tables were uploaded before The menus INPUT and IP OUT then are hidden In point 5...

Page 14: ...n only with function Virtual station tables nicht bei Funktion virtuelle Programmtabellen not with function Virtual station tables Tuner A Tuner B Bx 4A 27500 DVB S SYMBOL Bx 4A 10600 MHz LNB off Bx 4 Tuner A OK INPUT DVB S QPSK 8PSK DTV off Hh DFV1 10600 9750 Bedienhinweise blättert Menüs vorwärts blättert Menüs rückwärts wählen die Eingabeposition wählt Untermenü stellen Werte ein speichert alle...

Page 15: ...1 7 off PKTS FEC IP 1 off UDP MODE PORT 1234 Bx 4 Das Erste IP OUT 1 on off UDP RTP 0 65535 copy off 10 9 20 19 Annex A Annex B copy 1 7 auto Bx 4A Menu CA Edit Die angezeigte Information ist abhängig vom verwendeten CA Modul The information displayed is dependent on the CA module used Bx 4A 01 03 Information MENU Bx 4A TV X 04 09 X entschlüsseln descrambling 0 nicht entschlüsseln no descrambling ...

Page 16: ...E M B A Bx 4 Defaults FACTORY Bx 4 STORE FACTORY M 001 016 IP 1 TV Das Erste Bx 4 ac3 txt sub eit OPTIONS AC3 ac3 TXT txt SUB sub EIT eit ON off all 01 IP 1 all AUDIO copy 1 7 copy constant unmodified IP 1 7 3 DATARATE 10 0 MB auto 2 80 0 MBits Page 14 Page 14 ...

Page 17: ...WR I 20 0x6DD0 BR Alpha T 1 10744 H 22000 EinsExtra Transponder I 10 0x7031 EinsExtra I 11 0x7032 EinsFestival I 12 0x7033 EinsPlus I 22 0x7034 Arte I 23 0x7035 Phoenix L Name 2 I 227 40 50 0 1234 T 1 12480 V 27500 DSF Transponder I 48 0x0384 DSF I 49 0x0033 Tele5 I 50 0x0020 Sonnenklar T 1 11954 H 27500 ZDF Transponder I 2 0x6D66 ZDF I 13 0x6D6B ZDF Info I 14 0x6D6E ZDF Neo I 15 0x6D70 ZDF Theate...

Page 18: ...qC input 4 9750 defines the LNB oscillator frequency of the low band input 10600 defines the LNB oscillator frequency of the high band input By appropriate entries of the oscillator frequencies e g HI and LO can be interchanged at the inputs Also C band entry is possible If an input is not used 0 must be entered for the oscillator frequency Example S 4 D4 0 5150 LO input not used C band at the HI ...

Page 19: ...i switch can be controlled by SAT configu ration and Polarity The control voltage which is present at the antenna input is not suitable as power supply of the switch Use an external power supply I 1 0x6DCA 0 AC3 EIT 10 2 ARD ARD I Identifier for IP address 1 Output IP address fourth number e g 227 40 50 1 Commas are the separators between the items 0x6DCA Service ID SID can be entered in hexadecim...

Page 20: ... hole table can be set F TXT AC3 F Identifier for flag setting TXT Teletext Commas are the separators between the items AC3 AC3 tone These flags are set for all services after this sequence for which flags are not set individually until other flags are set with a new flag setting sequence Programming for the transmitting cassettes HSPT 1000 T C O 474 0x0001 0x0100 HSPT 1000 T O 474 0x0001 0x0100 6...

Page 21: ...or B transmitting cassette 1 modulator A transmitting cassette 2 modulator B transmitting cassette 2 etc I 1 2 I Identifier for IP address 1 Input IP address fourth number e g 227 40 50 1 Commas are the separators between the items 2 LCN Logical Channel Number Because of a more easily explanation the digits 1 and 2 are used in this example In order to retain an overview we recommend to use the sam...

Page 22: ... in the command line HotelTransponder exe config txt 1 60000 O HotelTransponder exe starts the software config txt selects the text file 1 sets the default receiving table for example table 1 the first table in the text file 60000 sets the port This port must be identical with the port set in the UDP port setting page 27 O textfile is also uploaded to the transmitter cas settes If the text file sh...

Page 23: ...returns to the previous menus Switch on the head end station The display shows the software version e g V 44 The processor reads the cassettes data approx 10 seconds BE Remote please wait V 44 t 10 s Ein On Selecting the cassette Box 4 V 4 HOT SPTS 0 128 Box 1 Bx 1A C5 12 S3 24 TWIN SAT C07 Böx 4 C5 12 S3 24 TWIN SAT C07 Box 5 Select the cassette you want to program e g Box 4 by repeatedly pressin...

Page 24: ...e 1st receiving table from the text file is shown Use the buttons to select the receiving table wished Press the button The Setting the Ethernet parameters ETHERNET menu is acti vated Setting the Ethernet parameters In this menu you specify whether the Ethernet parameters for the cassette are entered automatically by a connected server DHCP or whether you want to enter them manually stat To assign...

Page 25: ...operate the cassette in a network an IP address must be assigned to each IPTV cassette If a manually setting of the Ethernet parameters is se lected set the IP address of the cassette in this menu If DHCP is selected the IP ADDR IP MASK and IP GATEWAY sub menus display the param eters that were assigned automatically by a connected DHCP server e g 192 168 0 128 The star in the display means that t...

Page 26: ... address wished Press the button The Setting the address of the gateway IP GATEWAY menu is activated Setting the address of the gateway The address of a gateway server router can be set in this menu If no gate way is used you can skip this setting Bx 4 192 168 0 1 IP GATEWAY Use the buttons to place the cursor under the digit of the IP address displayed to be set and use to set the IP address wish...

Page 27: ...ables is activated continue on page 38 or Selecting the input data stream INPUT virtual station tables is not activated is activated Selecting the input data stream In this menu you select the signal source for the selection of the services The data streams to be processed are provided by Tuner A and Tuner B Bx 4 Tuner A OK INPUT Press the buttons to select the signal source of the input data stre...

Page 28: ...the oscillator frequency of the LNB used Repeat the procedure by the quantity of the digits to be set Press the button The Setting the input symbol rate setting the DVB mode SYMBOL menu is activated Setting the input symbol rate Setting the DVB mode The symbol rates of the satellite transponders can be found in the current chan nel table of the satellite operator in various satellite magazines and...

Page 29: ...e input frequency If three dots appear in the second line of the display the cassette is in the station search mode Please wait until the process has finished Once the RF receiver has synchronised to the input signal any offset to the target frequency is displayed in MHz e g 1 8 If a question mark appears in the second line of the display there is no input signal present Check the configuration of...

Page 30: ...NER B LED indicator Indication Green Signal quality is good Yellow Signal quality is insufficient Red No signal Press the button Selection Tuner A and CA module installed The Setting the PID monitoring CA_PID Check menu is acti vated page 41 Selection Tuner B or Tuner A without CA module The Selecting the input data stream INPUT menu is activated page 27 If necessary set the input parameters of th...

Page 31: ...ct the IP output to be set IP OUT 1 IP OUT 12 In the second line of the display the service is indicated allocated to the IP output e g Das Erste If off is shown the output is deactivated To skip the settings of the output parameters press the button The Stuffing the output data rate DATAMODE menu is activated Press the button The Setting the IP addresses for the services OUT IP menu is activated ...

Page 32: ...selected an exclamation mark appears in the first line of the display beside the number of the IP output IP 1 227 40 50 1 OUT IP Allocating IP addresses to the outputs manually Press the buttons to position the cursor under the digit of the IP ad dress to be set Using the buttons set the IP address wished Allocating IP addresses to the outputs automatically Pressing the button the following output...

Page 33: ...to select the transmission protocol wished UDP The User Datagram Protocol is for the connectionless transmission of data without acknowledgement from the receiver RTP The Real time Transport Protocol additional transmits time informa tions for runtime error correction at receiver side Setting the port number Press the button to position the cursor under the port number e g 1234 Use the buttons to ...

Page 34: ...redundant data are transmitted so that the addressee can correct transmission errors IP 1 7 off PKTS FEC Defining the quantity of data packets Using the buttons define the quantity of MPEG data packets in one IP data packet 1 7 Setting 7 results the smallest overhead Setting the forward error correction Press the button to position the cursor under off In position off the forward error correction ...

Page 35: ...or to a fixed value IP 1 7 3 DATARATE 10 0 MB The sum of the output data rates of all IP outputs must not exceed 80 Mbps 100 BASE T interface The current needed data rate is shown on the left side in parentheses e g 7 3 MBits This indication is dropped at setting auto Use the buttons to position the cursor under the digit of the data rate displayed to be set Using the buttons set the desired data ...

Page 36: ... The 1st of 16 services is being allocated to the IP ad dress Das Erste Name of the service Further possible terms displayed RA Type of the service Radio For radio stations the background of the screen of the connected TV or test receiver is darkened HD HD reception The star means that the TV or radio station selected is scrambled To enable the stations the CA module and the appropriate smart card...

Page 37: ...sired audio stream from the transport stream in this menu IP 1 all AUDIO Press to select the desired sound option e g all deu German etc Press the button The Switching DVB service information on or off OPTIONS menu is activated Switching DVB service information on or off In this menu the transmission of the DVB services AC3 AC3 sound TXT Teletext SUB subtitle EIT Event Information Table can be act...

Page 38: ...he settings until all outputs are set Press the button The Stuffing the output data rate DATAMODE menu is activated Stuffing the output data rate In this menu it is to set whether the current output data rate remains unmodi fied or whether it is stuffed to a constant value This value is a little bit higher than the current maximum output data rate and will be customized is necessary Bx 4 constant ...

Page 39: ... returned to the menu item Selecting the station table LOCATION virtual station ta bles is activated or Setting the Ethernet parameters ETHERNET virtual station tables is not activated without invoking the fac tory defaults page 24 Press the button The factory defaults are saved The display shows STORE Back to Selecting the cassette page 23 By pressing the button you will be returned to the menu i...

Page 40: ... 40 HDTV 1000 S Saving settings Press the button Back to Selecting the cassette page 23 The settings are saved ...

Page 41: ...lly the PID monitoring can be switched off Bx 4A PID Check CA on Use the buttons to switch off or on the PID monitoring Press the button The Configuring the CA module CA menu is activated Configuring the CA module The menu varies according to which CA module you are using For this rea son please refer to the operating manual of your particular CA module The relevant information is shown in the dis...

Page 42: ... module is activated For the explanation of further details please use the operating instructions of the CA module used Use the buttons to activate the submenu desired Press the button to activate the submenu To set the CA module use the and buttons Press the button to leave the submenu Press the button to return to the Configuring the CA module CA menu Press the button The Descrambling services E...

Page 43: ...ing of the indicators in the example Bx 4A Slot 4 channel strip Tuner A TV Television type of service X The currently selected service will be descrambled 04 09 The 4th of 9 services read is being displayed Name of the service Further possible terms displayed RA Radio type of service HD HD reception 0 The currently selected service remains unchanged Use the buttons to call up the services in seque...

Page 44: ...is activated page 27 6 Final procedures After installing the head end station upgrading accessories or installing cas settes it is necessary to tighten all cable connections cable terminals and cover screws in order to maintain compliance with current EMC regulations securely Securely tighten the cable bolted connections using an appropriate open ended spanner Mount the front cover see assembly in...

Page 45: ... 45 HDTV 1000 S Declaration of CE conformity ...

Page 46: ...Alterations reserved Technical data E O E by GSS GmbH V4 23072013 Service Phone 49 0 911 703 2221 Fax 49 0 911 703 2326 Email service gss de ...

Reviews: