background image

 

 

 

 

SELECTING GLASS TYPE  
AND COVERAGE RANGE. 

 

Set the jumper W1 according to the 
distance to the protected glass. 

 

Set the jumper W2 according to the 
protected glass type (see the figure).

 

 

TM
LW

PL

9
12

6

GLASS  TYPE

RANGE  ADJUSTMENT

W2

W1

PL

- PLATE

TM

- TEMPERED

LW

- LAMINATED
- WIRED
- COATED  

- SEALED INSULATING

- PATTERNED

*

M
M

M

TM

 position – for most glass types.

*

(TRIPLEX)

 

 

TM
LW

PL

RELAY

TAMPER   

9m

12m

6m

GLASS  TYPE

RANGE  ADJUSTMENT

S2

OFF

ON

GLASS TEST

OFF

ON

MEMORY

DIGITAL 

ACOUSTIC 

GLASS BREAK 

DETECTOR

G.S.N. 
ELECTRONIC 
COMPANY  LTD.

+ 12V

CS

YELLOW

RED

GREEN

S3

PATROL-501

S1

W2

W1

J1

 

 

LAST EVENT MEMORY. 

 

Set the jumper S3 to 

“ON”

 position 

for LED to provide indication of event 
memory function for last 30 minutes.

 

LED starts blinking on alarm.  
After the

 

period of 30 minutes the 

memory is automatically erased. 
 

 

 

             

S3

OFF

ON

MEMORY

 

 

 

 

 

GLASS BREAK  
SIMULATION TEST. 

1. Set jumper S2 to “ON” position.  
The yellow LED will be ON – the 
detector is in the “TEST” mode. 

2. Replace the cover.  

3. Use “FG-701” or “RG-65” Glass 
Break simulator or any other models 
to simulate the high frequency signal 
of the glass breakage. The red LED 
will flash on each simulator  
activation.  

     

S2

OFF

ON

GLASS TEST

 

 

GLASS BREAK SIMULATOR 

– MODEL FG-701

ACTIVATE

TEST

FLEX

MAN

BUTTON 

OF START

NO MORE THAN 12 METERS

HIGH FREQUENCY TEST

 

ATTENTION! 

 

During the “Glass Break Test” the 
alarm relay is opened. After

 

the 

“Glass Break Test” set jumper S2  
to “OFF” position (operating mode). 

 

SHOCK & GLASS BREAK 
SIMULATION TEST. 

 

The test is conducted in operating 
mode (“OFF” position).

 

 

      

S2

OFF

ON

GLASS TEST

 

 
Replace the cover. Tap gently the 
protected glass and activate the 
simulator at the same time.  
The red LED will be ON for 3 sec.   

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS. 

 

Power input:.…...………..9 - 16VDC 

 

Current consumption 

 

In stand-by mode:...………..17.8mA 

 

In alarm mode:...…………...18.7mA 

 

Alarm period:...…..………….…3sec. 

 

Warm up period: ………………2sec. 

 

Detection range:...……..12m x 170º 

 

Relay output:………….…………….. 
……………..N.C; 60V; 120mA; 16

 

 

Tamper:…..........................N.C.10

  

 

 

 

 

Microphone type:…...……………….. 
omnidirectional electret microphone 

 

Operating temperature 
range:……………..…– 30°C + 50°C 

 

Storage temperature  
range:………….…….– 40°C + 80°C 

 

RFI immunity:…………..30 V/m at a 
frequency range   10MHz-1000MHz 

 

EMI immunity:.……………..50 000V 

 

Dimensions:…….…….87x52x24mm

 

Weight:…………………………..58gr.
 
 
 

 

WARRANTY. 

 

GSN Electronic Company Ltd.

 

warrants the product to be free  
from defects in materials and 
workmanship under condition of 
observance of service regulations 
and to be repaired or replaced  
under absence of mechanical 
damages for a limited period of  
five years from the date of sale.

 

 

 
 
 
 
 
 
 
 

 

 
 
 
P/N: USM0E501 REV.A                         PRINTED IN ISRAEL

 

 

 

 
 