GSM mistral ML506 Instruction Manual Download Page 2

2

Important Safeguards

•   This bathroom heater is not intended for use 

by persons (including children) with reduced 

physical, sensory or mental capabilities, 

or lack of experience and knowledge, 

unless they have been given supervision or 

instruction concerning use of the appliance 

by a person responsible for their safety.

•   Children should be supervised to ensure that 

they do not play with the appliance.(i.e. wall 

switch)

•   Ensure that the switch is in the off position 

when changing the heat lamp (globe) or 

light globe.

•   Ensure that the wattage of the centre   

 replacement light globe is the same as the 

globe supplied with the unit. 

•  E27 275W heat globes can be used in this unit. 

•    Ensure the grille is free of objects, dust build 

up, etc. Make sure that the airflow through 

the grille is not inhibited.

•   Means for disconnection must be 

incorporated in the fixed wiring, in 

accordance with the wiring rules.

•   Precautions must be taken to avoid the back- 

 flow of gases into the room from the open 

flue of gas or other fuel burning appliances.

•   When cutting the ceiling material, care must 

be taken to ensure you do not damage 

electrical wiring and other hidden utilities.

•   This bathroom heater is to be installed so 

that switches or other controls can not be 

touched by a person in the bath or shower.

•   The lamps are extremely hot when in use. Do 

not touch to the lamps with any part of your 

body when in use. Allow all lamps cool down 

sufficiently before touching or replacement.

•   The appliance shall, under no circumstances, 

be covered with insulating material or similar 

material.

Cleaning

•   Ensure the Mistral bathroom heater is switch 

off and cool down sufficiently before 

cleaning.

•   Remove globes when they are at room 

temperature. Wipe with a damp cloth, never  

 immerse.

•   Unclip lamp surround and wash in warm 

soapy water. Always use a soft cloth, never 

abrasives.

•   Clean away any excess fluff from the inside of  

 the body, motor blade brackets.

•  The exhaust fan requires regular cleaning 

to ensure optimum performance. With the 

power off, regularly wipe the fan clear of dust 

and dirt. 

•  Clean the exhaust ducting kit, ensuring there 

are no obstructions at the exit.

Warning

If the power cord is damaged, the power cord 

must be replaced by either the service agent 

or similarly qualified persons in order to avoid a 

hazard.

This product has not been designed for any uses 

other than those specified in this booklet.

Save These Instructions

Summary of Contents for mistral ML506

Page 1: ...3 In 1 Bathroom Heater Model ML506 Instruction Manual ...

Page 2: ...amage electrical wiring and other hidden utilities This bathroom heater is to be installed so that switches or other controls can not be touched by a person in the bath or shower The lamps are extremely hot when in use Do not touch to the lamps with any part of your body when in use Allow all lamps cool down sufficiently before touching or replacement The appliance shall under no circumstances be ...

Page 3: ...rea requiring warmth Before you start make sure your ceiling has at least 280mm clearance from the roof see to the Mounting diagram Where to Locate Radiant globe heaters are not designed to heat entire rooms They provide instant concentrated heat to persons standing directly below the heat lamps Therefore Mistral Bathroom heater should be located over the area where drying off takes place not dire...

Page 4: ...er and accessories from the plastic bag and carton Please assemble the air outlet before mounting the unit into the hole Air outlet assemble steps as below 4 Connect the ducting if required to the outer grille of the unit Insert the unit into the square hole being sure to pull the side clips inward so that the body can pass through the hole without damaging the plaster Rotate the swing clips to ho...

Page 5: ... and fix another end of duct to vent louvres with metal clip Electrican s Wiring Instructions Your Mistral Bathroom Heater requires a 220 240 Volt 50Hz electrical supply All electrical work must be carried out by a qualified electrician and installed in accordance with relevant Electrical Wiring Regulations Your new Mistral Bathroom Heater comes with all required switches and mounting plates How 1...

Page 6: ...omatically When cool down the fan will close accordingly Replacement of Lamp 1 Check and tighten lamp regularly 2 Shut off power before replacement 3 Use E27 6W LED for lighting 4 Use E27 275W infrared lamp for heating Technical Specifications Power Supply AC 220 240V 50Hz Power Consumption 581W 2 x 275W Heat lamps 6W LED Light NOTE As a result of continual improvements the design and specificatio...

Page 7: ... goods come with guarantees which cannot be excluded under the Australian Consumer Law if purchased in Australia or the Consumer Guarantees Act 1993 if purchased in New Zealand You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of accep...

Page 8: ...8 Cat No ML506 April 2020 ...