background image

SWB240R-R2

Page 3 of 4

Unit 2, 110 Station Rd, Seven Hills ,NSW,  2147, Australia

Traveller Series

240VAC Sine Wave Power Inverter

Operating Instructions

Please read these instructions before use

SWB240R-R2

Model:

SWB1000-12, SWB1000-24

SWB1800-12, SWB1800-24

SWB2500-12, SWB2500-24

2.

 

Making DC Wiring Connections:

 Follow this procedure to connect the battery cables to the DC input terminals on the       

    inverter. Your cables should be as short as possible (ideally, less than 10 feet / 3 metres). 

a. 

Unpack and inspect the power inverter, check to see that the power switch in the OFF position.

b. 

Connect the DC POSITIVE cable to the Positive (POS+) terminal on the battery.

c.

 Connect the cable to the Positive terminal on the inverter. 

d.

 Connect the DC NEGATIVE cable to the Negative terminal on the inverter.

e.

 Connect the cable to the Negative (NEG-) terminal of the battery. This should be the last connection made. A spark  

    when making this final connection is normal. 

CAUTION! - 

 Reversed polarity connections will blow a fuse in inverter and may permanently damage the inverter.

Damage caused by a reverse polarity connection is not covered by our warranty.

WARNING!

 - You may observe a spark when you make this connection. Do not make this connection in 

the presence of flammable fumes. Explosion or fire may result.

WARNING! - 

 Make sure all the DC connections are tight. Loose connections will overheat and could 

result in a fire hazard.

Maintenance:

Helpful Tip to Conserve Battery Power

Should the inverter not be used over an extended period of time, it is recommended that the battery be disconnected 
from the inverter. This will ensure battery will not be drained over the period of non-usage.

Very little maintenance is required to keep your inverter operating properly. You should clean the exterior of the unit 

periodically with a damp cloth to prevent accumulation of dust and dirt. At the same time, tighten the screws on the DC 
input terminals.  

WARNING!

Do not open or disassemble inverter. Attempting to service the unit yourself may result in a risk of electrical shock or fire.   

Opperation:

1) Press the power button for 3-5 Seconds, Unit will turn ON. 

2) If the Left indicator is on then the Display will show the Input Voltage

3) If you desire to see the output power being used as a percentage press the power button with a quick short press 

once. Now the Right LED will be lit and the display will show the Output Power Consumpton as a Percentage of the 

total watts of the unit. 

4) If you wish to return to viewing the Input Voltage press the power button quickly once more. 

5) To turn OFF the unit press the power button for 3-5 Seconds. 

Summary of Contents for SWB1000-12

Page 1: ...y with soap and water If acid gets into eyes immediately flood eyes with running cold water for at least 20 minutes and get medical attention immediately NEVER smoke allow a spark or flame in the vicinity of batteries or engine Do not drop a metal tool on the battery as the resulting spark or short circuit of the battery may cause an explosion Remove personal metal items such as rings bracelets ne...

Page 2: ...t allow water to drip or splash on the inverter and in an area free of salt or moisture laden air Temperature Ambient air temperature should be between 0º and 40º Ventilation Allow at least twenty five millimeters one inch of clearance around the inverter for airflow Ensure the ventilation openings on the rear and bottom of the unit are not obstructed The installation site should not be susceptibl...

Page 3: ...his connection in the presence of flammable fumes Explosion or fire may result WARNING Make sure all the DC connections are tight Loose connections will overheat and could result in a fire hazard Maintenance Helpful Tip to Conserve Battery Power Should the inverter not be used over an extended period of time it is recommended that the battery be disconnected from the inverter This will ensure batt...

Page 4: ...uses 12V 24V 35A x 4 20A x4 30A x 8 15A x 8 40A x 8 20A x 8 Sine Wave Observation Smooth No Burr No Load or Load Total Harmonic Distortion 3 Fan Control Thermal and Load Controlled Over Temperature Cutout 60 C 70 C Overload Protection sustatined 5 30sec 1230W 2050W 2750W USB 5V 1A Working Temerature Range 10 C 40 C Warranty Conditions Our products come with guarantees that cannot be excluded under...

Reviews: