Modified Sine Wave

 DC to 240VAC Power Inverters

12VD

Operating Instructions

Please read these instructions before use

Maintenance:

Very little maintenance is required to keep your inverter operating properly. You should clean the 

exterior of the unit periodically with a dry cloth to prevent accumulation of dust and dirt. Do NOT 

use cleaning chemicals or water.

Remember to remove all plugs from GPO’s when cleaning the inverter and at the same 

time, check and tighten the screws if necessary on the DC input terminals.

Helpful Tip to Conserve Battery Power:

Should the inverter not be used over an extended period of time, it is recommended that the 

battery be disconnected from the inverter. This will ensure battery will not be drained over the 

period of non-usage.

Before Use:

1. 

 Unpack and inspect the power inverter, check to see that the power switch in the OFF position.

2.

  Connect the DC POSITIVE cable to the Positive (POS+) terminal on the battery.

3. 

 Connect the cable to the Positive terminal on the inverter.

4. 

 Connect the DC NEGATIVE cable to the Negative terminal on the inverter.

5.

  Connect the cable to the Negative (NEG-) terminal of the battery. This should be the last       

      connection made. A spark when making this final connection is normal. 

WARNING!

 • Make sure all the DC connections are tight. Loose connections will overheat and could 

 result in a fire hazard. • Do not operate the power inverter without connecting it to ground if used on 

a building site. Electrical shock hazard may result. • You may observe a spark when you make this  

connection. Do not make this connection in the presence of flammable fuse Explosion or 

fire may result.

Testing Unit after Connection:

1.

 Set the power switch to the ON position. Check the METERS and INDIDCATORS on the front 

panel of the inverter. The voltage bar graph will indicate the level of voltage from power source. If bar 

graph (1000/1500/2500) or LED (600W) does not indicate voltage, check the power source and the 

connections to inverter. The other indicators should be off.

2.

 Set power inverter switch to the OFF position. The indicator lights may blink and the internal alarm 

may sound momentarily. This is normal. Plug the test load into the AC GPO on the front panel of the 

inverter while still in the “off” position.

3.  

Set power inverter switch to the ON position and turn the test load on. The inverter should supply 

power to the load.

4.

  If you are operating several loads from the power inverter, switch them on separately after the 

inverter has been switched on. 

INV12-24-ALL-R1

Summary of Contents for INV600-12

Page 1: ...ot drop a metal tool on the battery as the resulting spark or short circuit of the battery may cause an explosion Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery produces a short circuit current high enough to weld a ring or similar metal causing a severe burn Operating Limits The inverter will operate most AC appl...

Page 2: ...V1000 1500 2500 only This bar graph displays the AC power drawn from the power inverter It indicates the load in Watts Under normal operating conditions the bar graph should display in the green or orange bars of the display If the load is excessive the number of bars being displayed will increase Should all the bars illuminate the unit will shut down to protect itself as this is in overload condi...

Page 3: ...ter 5 Connect the cable to the Negative NEG terminal of the battery This should be the last connection made A spark when making this final connection is normal WARNING Make sure all the DC connections are tight Loose connections will overheat and could result in a fire hazard Do not operate the power inverter without connecting it to ground if used on a building site Electrical shock hazard may re...

Page 4: ...ut voltage Reduce if too high TV channel interference on some channels Connection of chassis ground lug at rear of inverter needs attention High power loads being used during TV viewing Ensure TV antenna providing a good signal DC power cables too long causing excessive radiated interference Check chassis ground lug is a solid connection Do not use high power loads Check antenna wiring and connect...

Reviews: