1500W Solar Battery Charger
Booster Maximum Power Point Tracker
Operating Instructions
Please read these instructions before use
Model:
BMPPT1500
BASIC WIRING OPTIONS:
Permanent Load Connection
(Figure 1):
Simplest wiring option where the
load is permanently connected
and the batteries are not
protected from overdischarge.
Wiring With Low Voltage
Disconnect (Figure 2) :
This option protects the
battery from overdischarge by
disconnecting the load. The
LVD option disconnects the
load when the battery voltage
drops below 0.85 of nominal
voltage to protect the battery
from damage. The load
reconnects when the battery
voltage exceeds 0.95 of
nominal voltage. This feature
will not trigger during short
transients. LVD load is 40A
continuous or 60A transient.
Figure 2.
BMPPT1500-R1
Figure 1.