The ones switch is in increments of one second and the tens switch is in increments of ten seconds. As an
example, to set the motor timer to 20 seconds, turn the tens rotor to setting 2 and turn the ones setting to 0. The
solenoid timer setting would be set in the same manner.
4.1.9.5 Solenoid Timer Switches (Tens & Ones)
These rotary switches can be adjusted to vary the length of time the clutch solenoid is energized to allow the auger
tube to rotate in the product stream during each sample collection cycle.
NOTE:
THE CLUTCH SOLENOID TIME IS ADJUSTED SO THAT THE AUGER TUBE MAKES ONE
REVOLUTION. WHEN THIS TIMER TIMES OUT THE SOLENOID WILL STAY ENERGIZED VIA THE FIELD
WIRING THRU THE LIMIT SWITCH. WHEN THE LIMIT SWITCH IS ACTIVATED POWER TO THE SOLENOID
WILL CEASE AND THE CLUTCH WILL NO LONGER DRIVE THE AUGER TUBE. IF ADDITIONAL
REVOLUTIONS ARE DESIRED: ADD SIX SECONDS TO THE SOLENOID AND MOTOR TIMER SETTINGS
FOR EACH ADDITIONAL REVOLUTION.
Utilizing a small screw driver turn the slotted rotor of the tens and/or ones switches to desired length of time the
sample tube clutch solenoid is energized during a cycle. The time period can be adjusted from 1 to 99 seconds.
The timer is factory set at 4 seconds. Refer to Section 4.1.9.4 for further explanation on time settings.
4.1.9.6 Motor LED Indicator
This LED (D1) is illuminated when power is present to K-1 relay coil on the PC board. It is a visual signal showing
when the motor should be running.
4.1.9.7 Solenoid LED Indicator
This LED (D2) is illuminated when power is present to K-2 relay coil on the PC board. It is a visual signal showing
when the clutch solenoid should be energized.
4.1.9.8 Mode Select Switch
The switch, located at the lower center of the circuit board, determines the sequencing of certain internal controller
events.
As this board is used in controllers for several different samplers, MODE switch settings allow the board's
functions to be tailored to the requirements of the various samplers.
NOTE:
GSS-U SAMPLERS REQUIRE THE MODE SWITCH TO BE POSITIONED ON SETTING "2" (TWO).
IF THE MODE SETTING IS NOT CORRECTLY SET, TURN POWER OFF TO THE CONTROL PRIOR TO RE-
SELECTING. THE PC BOARD WILL ONLY CHANGE MODES WHEN POWER IS INITIALLY APPLIED.
4.1.9.9 Terminal Strip
This 20-position barrier terminal strip is located along the left edge of the circuit board. It serves as the controller's
interface and connection point for all external circuits and for the components mounted on the enclosure's front
panel. Refer to the certified electrical drawing(s).