![GSi Domestic - Mod/F Installation Manual Download Page 19](http://html.mh-extra.com/html/gsi/domestic-mod-f/domestic-mod-f_installation-manual_2275000019.webp)
2. Domestic Mod Wiring Diagrams
PNEG-2075
Modular Tower Dryer Wiring Diagrams for Domestic
19
Domestic Mod/T and F Dryers Terminal Strip Function (Page 3)
Figure 2D
11
22
33
44
5
5
66
7
7
88
99
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
25
25
26
26
27
27
28
28
29
29
30
30
31
31
32
32
33
33
34
34
35
35
36
36
37
37
38
38
39
39
40
40
AC1 - CONTROL PANEL CONNECTION
ACN - CONTROL PANEL CONNECTION
J6-01 - CONTROL PANEL CONNECTION
GND - CONTROL PANEL CONNECTION
LITE - CONTROL PANEL CONNECTION
J7-01 - CONTROL PANEL CONNECTION
BINDICATOR MOTOR 120V
TO VENT VALVE/LIQUID SOLENOID
CYCLE SOLENOID (N/A W/MODULATING)
BINDICATOR MOTOR NEUTRAL
CYCLE SOLENOID NEUTRAL
GAS VALVE NEUTRAL/LITE NEUTRAL
LITE
MJ7-01
GND
BINDICATOR (COM) +12 MAIN IO
+12V (MJ2-01)
+12V (MJ2-01)
DISCHARGE SWITCH (MJ1-08)
USER SAFETY #4 (MJ2-06)
USER SUPPLIED SAFETY (MJ2-04
AIR SYSTEM INTERLOCK (MJ1-10)
BINDICATOR (N/C)
-12V MAIN IO
GND
GRAIN TEMP (WHT)
GRAIN TEMP (BLK)
PLENUM TEMP (WHT)
PLENUM TEMP (BLK)
GND
GRAIN TEMP (WHT)
FROM ESTOP
FROM TRANSFORMER L-2 (ACN)
MJ6-01
GND
LITE
MJ7-01
MJ1-03
TO S.S. TERM A1 & 97
FJ1-01
FJ1-02
FJ1-04
BCM # X3-04/4
TO S.S. TERM A2
MJ6-02
MJ7-02
JUMPER TO TERM 5
JUMPER TO TERM 6
GND
MJ2-01
JUMPER TO TERM 31
JUMPER TO TERM 29 & 30
JUMPER TO TERM 28
MJ1-06
MJ2-06
MJ2-04
MJ1-10
MJ2-08
MJ2-10
GND
FJ3-04
FJ3-03
FJ3-02
FJ3-01
GND
FJ5-03
41
41
42
42
43
43
44
44
45
45
46
46
47
47
48
48
49
49
50
50
51
51
52
52
53
53
54
54
55
55
56
56
57
57
58
58
59
59
60
60
61
61
62
62
63
63
64
64
65
65
66
66
67
67
68
68
69
69
70
70
71
71
72
72
+12V FAN HEATER
AIRSWITCH COMMON
HOUSING HI-LIMIT
VAPOR HI-LIMIT & GAS PRESSURE SWITCH COM
PLENUM HI-LIMIT
TOP OV12V
MID/TOP OVERHEAT TEST POINT (OR OUTSIDE OVERHEAT-MOD'S)
HOUSING HI-LIMIT
PLENUM ADJUSTABLE HI-LIMIT
FROM HI-LIMIT (JUMP TO TERM 44 IF NOT L.P. FUEL
LOW GAS PRESSURE SWITCH (JUMP TO +12V IF NOT USED)
MID/BOTTOM OVERHEAT TEST POINT
BOTTOM OVERHEAT
AIRSWITCH N/O
HIGH GAS PRESSURE SWITCH (JUMP TO +12V IF NOT USED
GND
MODUTROL MOTOR "+"
MODUTROL MOTOR "-"
MAIN SOLENOID VALVES
MAIN SOLENOID VALVES NEUTRAL
BURNER FLAME ROD
BURNER GND
MOD VALVE SWITCH (JUMP TO 66 IF NO MOD VALVE)
MOD VALVE SWITCH (JUMP TO 65 IF NO MOD VALVE)
UV FLAME SENSOR (+) (T&F ONLY)
UV FLAME SENSOR (-) (T&F ONLY)
MAXON #1 TERMINAL #7
MAXON #1 TERMINAL #8
FJ4-01
(MOD'S ONLY FJ4-06)
(T&F ONLY FJ4-06)
FJ4-04
FJ4-09
FJ4-05
FJ4-07
FJ4-02
FJ4-08
GND
MOD BOARD POS.
MOD BOARD NEG.
X7-01/3 & J1-01
X7-01/2 (NEUTRAL)
X10-05/2
X10-05/1
BCM # X10-06/1
BCM # X10-06/2
EXTERNAL
INTERNAL
EXTERNAL
INTERNAL
MAXON #2 TERMINAL #7
MAXON #2 TERMINAL #8
1."F" TERMINALS ON FAN/HEATER BOARD
2."M" TERMINALS ON MAIN I/O BOARD
3."X" TERMINALS ON SIEMENS BURNER CONTROL
NOTES:
Summary of Contents for Domestic - Mod/F
Page 12: ...12 PNEG 2075 Modular Tower Dryer Wiring Diagrams for Domestic NOTES ...
Page 13: ... PNEG 2075 Modular Tower Dryer Wiring Diagrams for Domestic 13 Domestic Mod Wiring Diagrams ...
Page 34: ...34 PNEG 2075 Modular Tower Dryer Wiring Diagrams for Domestic NOTES ...
Page 56: ...56 PNEG 2075 Modular Tower Dryer Wiring Diagrams for Domestic NOTES ...