2. Installation
PNEG-1813
Electronic Distributor Control
15
Proximity Sensor Adjustment
Set the clearance of the two proximity sensors (DEC0018) to 0.110” +/- 0.01” from the face of each sensor
to the flag on the shaft (DEC0009).
Figure 2G
Proximity Sensor Adjustment
Proximity sensor
(DEC0018)
Flag
0.110” +/- 0.01”