![GSI Group PNEG-1499 Owner'S Manual Download Page 10](http://html1.mh-extra.com/html/gsi-group/pneg-1499/pneg-1499_owners-manual_2275204010.webp)
10
PNEG-1499 High / Low Thermostat
ELECTRICAL CONNECTION
Standard electrical safety practices and codes
should be used when working with a heater. Refer
to the National Electric Code Standard Handbook
by the National Fire Protection Association. A quali-
fied electrician should make all wiring installations.
DANGER
ALWAYS DISCONNECT AND LOCK OUT POWER
BEFORE WORKING ON OR AROUND HEATER.
Thermostat Connection to
Standard Terminal Strip
1.
Connect power cord to fan control box.
2.
Connect the BLACK 120VAC power wire
to terminal 2.
3.
Connect the WHITE Neutral wire to
terminal 8.
4.
Connect the BLUE Stage 1 N/O wire to
terminal 5.
5.
Connect the ORANGE Stage 1 Common
wire to terminal 8.
6.
Connect the RED Stage 2 Common wire
to terminal 6.
7.
Connect the GREEN Stage 2 N/O wire
to the high/low light.