GSI Group PNEG-1499 Owner'S Manual Download Page 10

10

PNEG-1499     High / Low Thermostat

ELECTRICAL CONNECTION

Standard  electrical  safety  practices  and  codes

should be used when working with a heater.  Refer

to  the  National  Electric  Code  Standard  Handbook

by the National Fire Protection Association.  A quali-

fied electrician should make all wiring installations.

DANGER

ALWAYS DISCONNECT AND LOCK OUT POWER

BEFORE WORKING ON OR AROUND HEATER.

Thermostat Connection to

Standard Terminal Strip

1.

Connect power cord to fan control box.

2.

Connect the BLACK 120VAC power wire

to terminal 2.

3.

Connect the WHITE Neutral wire to

terminal 8.

4.

Connect the BLUE Stage 1 N/O wire to

terminal 5.

5.

Connect the ORANGE Stage 1 Common

wire to terminal 8.

6.

Connect the RED Stage 2 Common wire

to terminal 6.

7.

Connect the GREEN Stage 2 N/O wire

to the high/low light.

Summary of Contents for PNEG-1499

Page 1: ...1 PNEG 1499 High Low Thermostat Digital High Low Thermostat INSTALLATION AND OPERATION PNEG 1499 PNEG 1499 Date 2 1 06...

Page 2: ...5 _____ d Value 4 set to H1 _____ e Value 5 or S2 set to 100 _____ f Value 6 or DIF2 set to 5 _____ g Value 7 set to H2 _____ 3 All items included in packaging _____ 4 Safety Decal Installed on side...

Page 3: ...4 Safety Guidelines 4 Safety Decals 7 Roof Damage Warning and Disclaimer 8 Installation 9 Thermostat Connection to Standard Heater Control 10 Thermostat Connection to Deluxe Heater Control 11 Program...

Page 4: ...lead to serious injury or death SAFETY GUIDELINES DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury This is the safety alert symbol It is...

Page 5: ...rn or broken parts Remove any build up grease oil or debris FOLLOW SAFETY INSTRUCTIONS Carefully read all safety messages in this manual and safety signs on your equipment Keep signs in good condition...

Page 6: ...to help protect your head and toes from falling debris Eye Protection Gloves Steel Toe Boots Respirator Hard Hat INSTALL OPERATE ELECTRICAL EQUIPMENT PROPERLY Electrical controls should be installed b...

Page 7: ...nd understood by all people in the grain handling area If a decal is damaged or is missing contact The GSI Group Inc 1004 E Illinois St Assumption IL 62510 217 226 4421 A free replacement will be sent...

Page 8: ...ve and modify prod ucts at any time without obligation to make changes improvements and modifications on equipment sold pre viously The principal concern of the The GSI Group Inc GSI is your safety an...

Page 9: ...he C 8058 plate on the sidewall The large hole on the plate should be centered on a valley of the bin corrugations The plate should be mounted approximately in the center of the plenum at the closest...

Page 10: ...tallations DANGER ALWAYS DISCONNECT AND LOCK OUT POWER BEFORE WORKING ON OR AROUND HEATER Thermostat Connection to Standard Terminal Strip 1 Connect power cord to fan control box 2 Connect the BLACK 1...

Page 11: ...ct the BLACK 120VAC power wire to terminal 20 3 Connect the WHITE Neutral wire to terminal 19 4 Connect the BLUE Stage 1 N O wire to terminal 15 5 Connect the ORANGE Stage 1 Common wire to terminal 14...

Page 12: ...ld now flash at the left side of the screen Press the UP arrow to increase or the DOWN arrow to decrease the setpoint to the desired temperature Cycle Set Point If the plenum temperature increases abo...

Page 13: ...y Part Number Description 1 1 HF 8055 THERMOSTAT 2 STAGE DIGITAL 2 2 FH 1309 LOCK NUT 1 2 401 ARL 3 2 FH 1310 CONNECTOR 1 2 4 12 ft WR 186SEOW WIRE CLM 18 6 SEOW CTRL CBL 5 6 S 280 SCREW SDS 10 16x5 8...

Page 14: ...s are not properly stored in memory To Correct Check all settings and correct if necessary EP Appears when the probe is open shorted or sensing a temperature that is out of range To Correct Check to s...

Page 15: ...UALITY PROBLEMS MODIFICATIONS TO THE PRODUCT NOT SPECIFICALLY COVERED BY THE CONTENTS OF THIS MANUAL WILL NULLIFY ANY PRODUCT WAR RANTY THAT MIGHT HAVE BEEN OTHERWISE AVAILABLE THE FOREGOING WARRANTY...

Page 16: ...This Equipment shall be installed in accordance with the current installation codes and applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be...

Reviews: