5. 2.66" Corrugated Commercial Hopper Tank 4-9 Rings
28
PNEG-1451
Ladder, Safety Cage and Platform for Hopper Tanks
Eave Platform Mounting Angle Installation
shows the location of the platform mounting angles (B). Each angle must be mounted starting
4" below the top horizontal seam of the second ring with the first mounting angle offset 9-3/8" from the
right hand starter bracket (A). The second mounting angle must be located 56-1/4" from the first mounting
angle (B). The dimensions and locations of these angles are critical for proper fit of all parts. Using the
platform mounting angels (B) as guides, field drill 3/8" holes in the sidewall every 8".
Figure 5H
Ref #
Part #
Description
A
LDR-4347
R.H. Starter Bracket
B
TDP-5008N
Fluorescent Green/Black Platform Mounting Angles (Field drill 3/8" holes on 8" centers.)
C
Roof Ladder
D
Manway Panel
E
18-3/4" Reference
F
32" Typical