Wiring Diagrams
12V
Wiring Diagram with External IP3 Function
12V Linear
Power supply
Door Exit Button
0V
Door
Contact
0V
Common the OV from the
Fire Alarm Panel and the OV
from the Door Control to
avoid any ground loop issues.
Fire Alarm
Panel
0V
When the fire alarm
is activated (0V removed
from IP4) the door will
be opened
12V
Sounder
12V
0V
NO
COM
NC
12 - 24 VAC
12 - 24 VAC
Wiring for StikeLock only using 12 - 24VAC supply
Note: All OV shown in the
diagram are connected to
OV of the Door Control.
0V
0V
OP1
Follow
Relay
IP3
Data0/Data
IP4
Fire Alarm
IP2
Door
Contact
IP1
Door Exit
Button
OP2
Alarm/Sounder
12V DC
Only
0V
BreakGlass Unit
Note: Fire Alarm Override is
deactivated until the Door
Control joins a network.
16V
Varistor
16V
Varistor
12V
0V
NO
COM
NC
IP1
IP2
IP3
IP4
OP1
OP2
A
B
T
AMP
T
AMP
485 Network Connection A & B
Common the OV from the Door
Control and the COM on the
Controllers “Door Network”
when using the 485 interface.
Place a 120ohm Termination
Resistor across A & B at the
Controller and on the last Door
in the daisy chain.
12V
0V
NO
COM
NC
IP1
IP2
IP3
IP4
OP1
OP2
A
B
T
AMP
T
AMP
1
2
3
4
5
6
IP3
- Card and Pin
- Card or Pin
- Lock Door
(selectable from
“Doors” tab in PC
Application)
10
Wiring Diagrams
12V
Wiring Diagram with Interlock Connection
12V Linear
Power supply
Door Exit Button
0V
Door
Contact
0V
Common the OV from the
Fire Alarm Panel and the OV
from the Door Control to
avoid any ground loop issues.
Fire Alarm
Panel
0V
When the fire alarm
is activated (0V removed
from IP4) the door will
be opened
12V
Sounder
12V
0V
NO
COM
NC
12 - 24 VAC
12 - 24 VAC
Wiring for StikeLock only using 12 - 24VAC supply
Note: All OV shown in the
diagram are connected to
OV of the Door Control.
0V
0V
IP4
Fire Alarm
IP2
Door
Contact
IP1
Door Exit
Button
OP2
Alarm/Sounder
12V DC
Only
0V
BreakGlass Unit
Note: Fire Alarm Override is
deactivated until the Door
Control joins a network.
16V
Varistor
16V
Varistor
12V
0V
NO
COM
NC
IP1
IP2
IP3
IP4
OP1
OP2
A
B
T
AMP
T
AMP
485 Network Connection A & B
Common the OV from the Door
Control and the COM on the
Controllers “Door Network”
when using the 485 interface.
Place a 120ohm Termination
Resistor across A & B at the
Controller and on the last Door
in the daisy chain.
12V
0V
NO
COM
NC
IP1
IP2
IP3
IP4
OP1
OP2
A
B
T
AMP
T
AMP
1
2
3
4
5
6
Interlock OP (OP1)
to Interlock IP on
2nd Door
Interlock IP (IP3) from
Interlock OP on
2nd Door