background image

20

Operation Instructions

Phase 6 - Downloading Configuration

Phase 5 - Configuring Access Levels

Step   Description

           Access Levels are controlled by creating UserGroups and assigning the
           UserGroup to a User as described in section ‘Configuring Users’.

   1.     

UserGroups

 are created by combining pairs of 

DoorGroups

 with

           

Timezones

. Each UserGroup can have up to 6 pairs of DoorGroups and

           Timezones. Select DoorGroups and Timezones from the drop-down menus
           to add to the current UserGroup.

   2.     

Timezones

 are the periods of time for each day of the week that access

           will be granted. Select times and tick the days of the week this time is valid.
           4 time periods can be created for each timezone. Select ‘Holiday Access’
           to grant access for holiday periods. Double click on the ‘Holiday Access’ to
           add days to the holiday periods. Use the calendar to select these days.

   3.     

DoorGroups

 are created by grouping doors together. e.g. all the entry and

           exit doors could be grouped together as ‘Peremiter Doors’. Select a Door
           from the ‘All available Doors’ window and drag it to the ‘Doors in Current
           Door Group’ to add it to  the Door Group. Repeat for adding each door.

Step   Description

           After all users, access levels and door control settings have been finalised,
           a full download to the controller should be carried out.

  1.      Go to the ‘Settings’ tab and click on ‘Download Configuration’. A pop-up
            window will appear, tracking the status of the download. All settings will be
            downloaded to the Controller and Door Controls.

 21

Operation Instructions

Enrolling User FingerPrints

Step   Description

           Note: Make sure the USB Fingerprint reader is attached to the PC

   1.     On the Users Tab , Select a User for fingerprint enrollment

   2.    Click on the ‘Fingerprints’ button.

   3.     Click on ‘+’ button to begin and place finger on the enrolment reader. An
           image of the fingerprint will appear on the screen. Ensure that the image
           quality is good and a value of at least 90% is achieved. Refer to section
           ‘Finger Placement’ for correct finger placement and example of good
           quality image. Repeat this process if this is not achieved on first attempt.

   4.     Click ‘Save’ using a good quality template only. Poor Quality templates can
           lead to false rejections later when trying to gain access .

Summary of Contents for Wi-Corporate Controller

Page 1: ...roducts from GSD 4 Installation Instructions 12 Network Diagrams Wiring Diagrams 19 Fingerprint Enrollment Operation Instructions Global Security Devices Ltd No 3 Broomhill Business Complex Tallaght Dublin 24 Ireland Phone 353 1 524 2691 Email info globalsecurity ie www globalsecurity ie YOUR SECURITY IS OUR PRIORITY ...

Page 2: ...rts Wireless RS485 Networks Automatic Backup Facility Database Encryption 30000 individual usergroups are available 20 30000 128 128 128 Yes Yes Unlimited CCTV Lift control Yes Yes Yes Installation Steps Step Description Page 1 Install the Controller using the Installation Diagrams 4 5 2 Wire the Controller using the Wiring Diagrams 8 3 Install and wire each Door Control Refer to the Door Control ...

Page 3: ...r pull out on right and slide left to remove cover pull forward on right and slide left mount with 4 x 1 5 inch No 8 Security Type screws rear tamper switch cable entry cable entry cable entry cable entry spare cap access to rear void for wiring spirit level mains pcb mount hole mount hole mount hole 4 Installation Diagrams 5 Installation Diagrams ...

Page 4: ...ommunication range depends on building shape and construction methods used 7 System Overview Note If using a single Controller an RS232 cable may be used Max cable length 10 meters RS485 Connection to Door Controls Door Control 1 Door Control 2 Door Control 3 Door Control 4 20 RS485 Network to Door Controls Max Cable Length 1 4 km Daisy Chain Configuration Only Controller 1 Controller 2 3 Note If ...

Page 5: ...a suitably qualified person only Cable Tie retaining clips Main Input Cable 230VAC Neutral Earth Live Remove Battery Tab Pull 9 Network Diagrams for Single Controller A B 0V TX RX A B 0V Door Network PC Network Connect DB9 cable to serial port on PC Maximum cable length 10 meters Direct Connect All Dip Switches OFF PC Direct DB9 Female Serial Cable PC Direct Connection can be used when using ONLY ...

Page 6: ... All OFF Address 1 Set SW1 ON Address 2 Set SW2 ON Note Address 3 Set SW3 ON only The Controller Address is set by configuring the Dip switches as shown below Configuring GSD Controller Communications Step Description 1 On the Controller Tab set the Connection Type to Serial 2 On the Settings tab in the communications section Select the Serial Port number from the drop down list connected to the C...

Page 7: ...ontroller e g 192 168 1 26 7 Make sure the controller is online and click on the Controller TCP IP Configuration button 8 Choose Static IP mode and enter the IP address Netmask and Default Gateway assigned by your network administrator Click Send new settings to Controller The Controller will now go offline as the new IP Address settings are applied 9 Connect the PC and Controller to your LAN and ...

Page 8: ...icon will change colour to show that the Controller is on line F Go to the Current Events tab and verify the log messages indicate the controller is on line 15 Operation Instructions Phase 2 Configuring the GSD Controller Step Description 1 Open the Doors tab in the main menu to add the required number of new doors to be part of this network One door will already be added by default Click on the b...

Page 9: ...complete 17 Operation Instructions Phase 3 Enrolling Door Controls Note For Wired 485 Door Controls right click on the Controller on the right hand side of the application and select Manually Assign Address from the drop down menu Once all new Door Controls are found by the Controller they will all beep with the number of the next available address door position on the Controller e g if door 2 is ...

Page 10: ...to inactive then access will be denied for all cards and PINs on that Door Control Example To Enable PIN codes only on a Wi PIN Prox Set the Timed Action Card or PIN to Inactive and set the Timed Action PIN Only to All day Every Day This will grant access for PIN codes and deny access for cards and fobs Phase 4 Configuring Users Step Description 1 Enable a User by ticking the Enabled box for each ...

Page 11: ...All available Doors window and drag it to the Doors in Current Door Group to add it to the Door Group Repeat for adding each door Step Description After all users access levels and door control settings have been finalised a full download to the controller should be carried out 1 Go to the Settings tab and click on Download Configuration A pop up window will appear tracking the status of the downl...

Page 12: ...Note The System does not store the finger print It uses an algorithm to generate a binary representation using sample points from the fingerprint It uses this information to then validate each users fingerprint Incorrect Finger Placement 23 Finger Placement Wi BIO Poor Quality Image Note Poor Quality image No Fingerprint core on sensor window This can result in poor template quality that can lead ...

Page 13: ...Correct Finger Placement 24 Finger Placement Wi BIO Incorrect Finger Placement 25 Finger Placement Wi BIO ...

Page 14: ... 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 Ctrl Door No Door Type Door Location Name Walk Test 1 2 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Ctrl Door No Door Type Door Location Name Walk Test 2 3 Installation Records ...

Reviews: