4.3.2. Connection cable

 

Use the appropriate cable for the connections to avoid overheating or 

unnecessary losses. It is better to use cables that are too thick. 
Screw the cable connections or GS-Power copper bars tightly (M8), a 

loose cable leads to high heat development. 

 

4.4. Connecting a charger to the battery 

 

Make sure you have completed all the steps previously 

described in chapter 4 before connecting the battery to the charger.

 

 

4.5. Disconnecting a battery 

  First disconnect the negative cable from the negative (-) terminal 

of the battery. 

  Disconnect the positive cable from the positive (+) terminal of the 

battery. 

 

General information

  

 

Follow the safety guidelines and measures in chapter 1. 

 

Never overcharge the LiFePO4 battery, as this will permanently 

damage the battery; only use a class 2 LiFePO4-capable charger. 

See, among other things, at:

 

"www.gs-power.net"

 

 

Before use, charge each LiFePO4 battery individually.

 

 

Disconnect the charger from the battery if it will not be used 

for a long time.

 

• 

Connect the charger according to the description. 

• 

Charge the battery in case of disconnection due to undervoltage 

or when the charge status drops below 20% to maintain battery 

life.

 

 

Summary of Contents for GV-12V100Ah

Page 1: ...Instruction manual GV 12V100Ah GV 12V100Ah Smart GV 12V200Ah Smart GV 24V100Ah Smart...

Page 2: ...he index at the beginning of this manual to find the information relevant to you While using the product user safety must always be ensured so that installers users maintenance personnel and third par...

Page 3: ...ols 2 Introduction 2 1 Product description 2 2 Intended use 2 3 Glossary of terminology 2 4 Symbols used 3 Product specifications 3 1 Technical data 3 1 1 Electrical characteristics 3 1 2 Mechanical c...

Page 4: ...ttery 4 3 2 Connecting cable 4 4 Connecting a charger to the battery 4 5 Disconnecting a battery 5 Use of the battery 5 1 Charging current 6 Inspection and cleaning 6 1 General information 6 2 Inspect...

Page 5: ...first and then connect the negative cable Do not mix batteries of different manufacturers capacities sizes or types Keep the LiFePO4 battery clean and dry Second batteries must be charged before use A...

Page 6: ...he battery from being charged below 0 C 1 2 Disposal Dispose the LiFePO4 battery in accordance with the local state and federal laws and regulations Batteries may be returned to the manufacturer Do no...

Page 7: ...handled differently from conventional lead acid batteries We would like to ask you to pay attention to the warnings indicated on the battery There is a risk of fire and burns if used improperly or car...

Page 8: ...is taken over by the BMS The batteries with BMS also switch off automatically in the event of overheating Do not connect several LiFePO4 batteries in series or parallel 2 3 Glossary of terms Life cyc...

Page 9: ...also serve as a reminder for the user 3 Product specifications 3 1 Technical data 3 1 1 Electrical property Label GV 12V100Ah GV 12V100Ah smart GV 12V200Ah smart GV 24V100Ah smart Capacity 100 Ah 200...

Page 10: ...C to 55 C Storage temperature short term 1 Month 20 C to 45 C Storage temperature long term 1 Month 0 C to 25 C Table 5 Temperature characteristics Do not charge the Li ion battery below 0 C 3 1 5 Con...

Page 11: ...ables in reverse polarity 4 2 Unpacking Check the LiFePO4 battery for damage after unpacking If the Li ion battery is damaged contact your specialist dealer or GS Power Do not install or use the LiFeP...

Page 12: ...gative cable from the negative terminal of the battery Disconnect the positive cable from the positive terminal of the battery General information Follow the safety guidelines and measures in chapter...

Page 13: ...nd maintenance work Place the enclosed protective caps on the positive pole before cleaning and maintenance work to prevent the poles from being touched Protect the poles from conductive parts spanner...

Page 14: ...ge or discharge the LiFePO4 battery to 75 of its capacity before storage Disconnect the LiFePO4 battery from all loads and if present from the charger During storage place a terminal cap over the LiFe...

Page 15: ...are damaged or the battery is used up Contact your retailer Tabelle 10 Fehlersuche 11 Warranty and liability o The customer is obliged to check immediately upon delivery whether the products have bee...

Page 16: ...or a particular purpose or any warranty arising out of a course of dealing course of performance or course of dealing usage GS Power specifically disclaims any representation or warranty that the prod...

Page 17: ...lity for property damage financial loss and bodily injury including death caused by the use of these particular GS Power Products shall in any event be limited to the amount actually paid out by GS Po...

Page 18: ...GS net GmbH Co KG Bachstr 15 63762 Gro ostheim Germany...