3. WORKING CONDITIONS AND NORMS
Optimum results from using this equipment can be obtained by meeting the following
requirements:
-
Install the Coin validator with a maximum inclination of +/- 3º on all axes.
-
Temperatures:
Ô
Storage: from -25 to +70ºC.
Ô
Working from +5 to +55ºC, at the extremes, double the percentage of normal coin
rejection for valid coins.
-
Humidity: maximum 95% (relative humidity without condensation)
-
Physical characteristics of the coins that are admitted:
Minimum
Maximum
Diameter
16.5 mm
32.5 mm
Thickness
1.2 mm
3,5 mm
The typical acceptance of legal currency is 97% on the first try (without deformations and
with standard electrical conductivity and magnetic permeability parameters).
-
Norms that are met.
Ô
EN50081-1. General emission norm
z
EN50022: Radiated emission (measurement of the radiated perturbation field).
z
EN50022: Conductive emission (measurement of the conductive perturbations
in power supply).
Ô
EN50082-1: General immunity norm.
z
IEC801-2: Electrostatic discharges (measurement of the immunity to
electrostatic discharges).
z
IEC801-3: Radiation immunity (measurement of the immunity to electric fields).
z
IEC801-4: Transitory peaks and spikes (Measurement of the immunity of
transitory peaks and spikes).
Ô
EN60335-1 (94-95). Electrical appliance safety norm
Ô
CE