background image

 
 

HT G11 / G12 GSM Terminal  

Instruction Manual 

 

  

GRUP ARGE ENERJİ VE KONTROL 

SİSTEMLERİ SAN. ve TİC. LTD. ŞTİ. 

 İkitelli OSB Mah. YTÜ İkitelli Teknopark Sok.

 

No: 1/2B1-2B7-2B8-2B9 Başakşehir / İstanbul 

Phone: +90 212 438 80 24 

Fax: +90 212 438 80 25

 

Technical Support:  

Phone: +90 212 438 61 17 

Mobile Phone: +90 549 650 50 53 

[email protected] 

www.gruparge.com

 

www.enerjitakibi.com

 

 

 

Version 19-2

  

 

Summary of Contents for HT G11

Page 1: ...AN ve T C LTD T kitelli OSB Mah YT kitelli Teknopark Sok No 1 2B1 2B7 2B8 2B9 Ba ak ehir stanbul Phone 90 212 438 80 24 Fax 90 212 438 80 25 Technical Support Phone 90 212 438 61 17 Mobile Phone 90 54...

Page 2: ...AC Supply Connection 10 3 2 DC Supply Connection 10 4 METER COMMUNICATION CONNECTIONS 11 4 1 Optical Port Connection 11 4 2 Makel RS 232 Communication Connection 12 4 3 Makel K hler Viko RS 485 Commu...

Page 3: ...count our company or the authorized dealer shall not be held responsible for the negative consequences Do not dispose in the trash the device must be delivered to the collection centers electronic dev...

Page 4: ...roperty should be inserted into the device If a PIN code is defined on the SIM card the PIN code must be canceled by inserting the SIM card into a mobile phone HT G11 G12 GSM communication terminals q...

Page 5: ...etween 1 240 minutes It has a system architecture which does not require static IP For the locations of weak GSM network signal it has wired GSM antenna support It is compatible with M2M SIM Cards of...

Page 6: ...HT G11 G12 GSM Terminal Instruction Manual 6 WARNING VDD TX RX GND A B terminals should not be connected to the mains Figure 1 1...

Page 7: ...t is attempting to establish a connection 3 No server connection is established 4 The SIM card is not inserted or the PIN code is not cancelled 5 It indicates a communication problem in RS 485 line 6...

Page 8: ...ure 3 4 3 5 3 6 3 7 3 8 3 9 d Modbus Device Relay analyzer etc RS 485 See Figure 4 1 4 2 3 Cancel the PIN code of the SIM card and insert into the SIM card slot as shown on the device 4 Operate the de...

Page 9: ...device and change the Modbus address 2 2 How to Use Authorized Code 1 Login to SmartPower Energy Monitoring System and go to Modem page 2 Click Add Modem Authorization button and enter the informatio...

Page 10: ...HT G11 G12 GSM Terminal Instruction Manual 10 3 SUPPLY CONNECTIONS 3 1 AC Supply Connection Figure 3 1 3 2 DC Supply Connection Figure 3 2...

Page 11: ...MUNICATION CONNECTIONS 4 1 Optical Port Connection Figure 4 1 NOTE When placing the optical reader on the meter make sure the arrow mark on the label points to upward direction Figure 4 2 Table 4 1 Ca...

Page 12: ...HT G11 G12 GSM Terminal Instruction Manual 12 4 2 Makel RS 232 Communication Connection Figure 4 3 4 3 Makel K hler Viko RS 485 Communication Connection Figure 4 4...

Page 13: ...M Terminal Instruction Manual 13 4 4 Elektromed Luna RS 485 Communication Connection 4 5 Elster RS 485 Communication Connection There are two RS 485 terminals in some models of Elster meters Figure 4...

Page 14: ...HT G11 G12 GSM Terminal Instruction Manual 14 4 6 EMH RS 485 Communication Connection Figure 4 8 Figure 4 7...

Page 15: ...struction Manual 15 4 7 Landis RS 485 Communication Connection NOTE In order to read Landis Meters via RS 485 the technical support line must be called and serial number of the meter must be introduce...

Page 16: ...d to B The connection of the different named devices is showed below NOTE The Modbus addresses and types of the devices that connected to modem must be defined by entering the setup page of the releva...

Page 17: ...HT G11 G12 GSM Terminal Instruction Manual 17 5 2 Klemsan Relay REMO Q and RAPIDUS Terminal Connection 6 SELECTION TABLE Table 6 1 Figure 5 2...