A L I G N M E N T      P R O C E D U R E

MODEL NO.:  GRUNDIG  RP5240LW

SIGNAL  SOURCE  (FM  Signal  Gen.) CONNECT TO

SET  SIGNAL TO

ALIGNMENT  INDICATOR  (Oscilloscope,  VTVM) CONNECT TO

SET  RADIO DIAL 

TO

ADJUST

ADJUST  FOR

REMARKS

L 4

87.35 MHz

(Lowest   end)

stretch or

(modulated)

squeeze

TP 1

108.25 MHz

Terminals

VC1 B

Volume

through matching network

(modulated)

across speaker 

(Highest  end)

(Osc. trimmer)

Maximum

control at

if necessary

voice coil

L 3 (RF coil)

max. position

88 MHz

88 MHz

stretch or

(modulated)

squeeze

106 MHz

VC1 C

(modulated)

106 MHz

 (RF trimmer)

  Repeat steps 3 and 4 as necessary to minimize tracking error and also steps 1 and 2 if necessary

ALIGNMENT

SIGNAL  SOURCE  (AM  Signal  Gen.) CONNECT TO

SET  SIGNAL TO

ALIGNMENT  INDICATOR  (Oscilloscope,  VTVM) CONNECT TO

SET  RADIO DIAL 

TO

ADJUST

ADJUST  FOR

REMARKS

515 KHz

L 5

(modulated)

(Lowest end)

(Osc. coil)

1640 KHz

VC1 A

Volume

A standard radiation

(modulated)

Across speaker

(Highest end)

(Osc. trimmer)

Maximum

control at

loop ant.

558 KHz

voice coil

L 2

max. position

(modulated)

558 KHz

(ant. coil)

1440 KHz

VC1 D

(modulated)

1440 KHz

(ant. trimmer)

  Repeat steps 3 and 4 as necessary to minimize tracking error and also steps 1 and 2 if necessary

ALIGNMENT

SIGNAL  SOURCE  (LW  Signal  Gen.) CONNECT TO

SET  SIGNAL TO

ALIGNMENT  INDICATOR  (Oscilloscope,  VTVM) CONNECT TO

SET  RADIO DIAL 

TO

ADJUST

ADJUST  FOR

REMARKS

142 KHZ

(modulated)

(Lowest end)

NA

292 KHz

Terminals

TC 3

Volume

A standard radiation

(modulated)

across speaker

(Highest end)

(Osc. trimmer)

Maximum

control at

loop ant.

153 KHz

voice coil

L 6

max. position

(modulated)

153 KHz

(ant. coil)

261 KHz

TC 4

(modulated)

261 KHz

(ant. trimmer)

  Repeat steps 3 and 4 as necessary to minimize tracking error and also steps 1 and 2 if necessary

Summary of Contents for Musik Boy 50L RP 5240 LW

Page 1: ...The regulations and safety instructions shall be valid as provided by the Safety Service Manual part number 720108000000 as well as the respective national deviations S Dieses Service Dokument ist nur in Datenform verfügbar This Service Document is only available as data Änderungen vorbehalten Subject to alteration Made by GRUNDIG in Germany H S43 0802 http www grundig com S Service Manual Sicherh...

Page 2: ...GNAL SOURCE AM RF Gen CONNECT TO SET SIGNAL TO ALIGNMENT INDICATOR Oscilloscope VTVM CONNECT TO SET RADIO DIAL TO ADJUST ADJUST FOR REMARKS TP 4 Volume control at 1 A standard radiation 460KHz Detector output terminal Quiet Maximum min position loop and TP 2 ground Point T 2 2 Repeat step 1 for max output FM IF ALIGNMENT This model requires no FM IF alignment as the IF is fixed by ceramic filter a...

Page 3: ...e VTVM CONNECT TO SET RADIO DIAL TO ADJUST ADJUST FOR REMARKS 515 KHz L 5 modulated Lowest end Osc coil 1640 KHz VC1 A Volume A standard radiation modulated Across speaker Highest end Osc trimmer Maximum control at loop ant 558 KHz voice coil L 2 max position modulated 558 KHz ant coil 1440 KHz VC1 D modulated 1440 KHz ant trimmer Repeat steps 3 and 4 as necessary to minimize tracking error and al...

Page 4: ...Musik Boy 50L RP 5240 LW ǵ ...

Page 5: ...Musik Boy 50L RP 5240 LW ǵ ...

Page 6: ...Musik Boy 50L RP 5240 LW ǵ ...

Page 7: ...Musik Boy 50L RP 5240 LW ǵ ...

Page 8: ...Musik Boy 50L RP 5240 LW ǵ ...

Reviews: