Heat Pump Space Heater 20
38
Whether the high pressure 2
switch is effective (system
parameter)
Middle pressure
Switch enable
0
0/1
0-enable
1-disable
1
39
Minimum opening setting
MinEEV
80/5
P
(0
~
480)/5
1
40
Minimum water temperature
requirement when entering
defrost
Tdf
10
℃
0
~
40
1
41
Ambient temperature of
pipeline electric heating
T4g
-20
℃
-40
~
20
1
42
Defrost exit temperature
Ft
15
℃
10
~
25
1
43
Maximum defrost operating
time
FT
10
Min
1
~
20
1
44
Return oil into the lowest
frequency
Fo
50
Hz
30
~
60
1
45
Test mode AC fan speed
TF
2
/
1-low speed
2-high speed
/
46
Chassis electric heating start
temperature
BHon
-5
℃
-15
~
0
1
47 Minimum operating frequency
Fmin
25
Hz
20
~
100
1
48
Heating mode switch
HeatChange
0
/
0/1
/
49
Correction of heating target
exhaust temperature
TargetTPh
0
℃
-10
~
15
1
50
EEPROM Reset
/
0
/
0-Normal
1-Reset
1
51
Standby water pump speed
SB-PWMout
35
%
10
~
100
1
52
Test mode DC fan speed
FspeedT
900/15
rpm 200
~
1000/15
1
53
Minimum DC fan speed
FanMin
250/15
rpm 200
~
500/15
1
54
Minimum DC fan speed
FanMax
825/15
rpm 500
~
1000/15
1
55
Maxmum DC fan speed
NoiseFan
650/15
rpm 300
~
1000/15
1
56
Cool coil pipe temp.
CondT
40
℃
20
~
60
1
57
Heat coil pipe temp.
EvapT
5
℃
-10
~
20
1
58
DC fan resonance point 1
SR1
0/15
rpm
0
~
1000/15
1
Summary of Contents for GHP-MM08
Page 27: ...27 EN Heat Pump Monobloc Inverter User Manual...
Page 28: ...28 EN Heat Pump Monobloc Inverter User Manual 3 9 2 GHP MM14 GHP MM16...
Page 29: ...29 EN Heat Pump Monobloc Inverter User Manual...
Page 72: ...72 EN Heat Pump Monobloc Inverter User Manual Figure 4 19 9 14 16kw...
Page 83: ...Beko Grundig Deutschland GmbH Rahmannstra e 3 65760 Eschborn www grundig com...