GDV 100 D
Service Test Programme
GRUNDIG Service
3 - 17
k
2. Manual System Test
The Manual System Test is a possibility to check which of the modules
(Keyboard Control Unit, Digital Board or Basic Engine) is faulty. In
addition to that, it is possible to check all ERRORS by reading the
ERROR log and the ERROR bits, including the ERRORS which have
appeared in the normal use of the DVD-Player. At the end of the
Manual System Test a Loop Test is started (the Service Test Levels of
the Automatic System Test are running in an endless loop).
For this test the DVD-Player has to be connected to a TV Set (PAL or
Multisystem), to control the results of the Service Test Levels.
To check the results of some Service Test Levels, the System Test
requires interactive actions from the user (e.g. confirmation of a
testpicture or a testsound). For some levels (e.g. levels for testing the
basic engine functions) the DVD-Player has to be opened to control the
function of the moveable components.
The test only checks functions, which can be checked by the Service
Test Software.
Start of the Manual System Test
Press 2 keys simultaneously
<OPEN/CLOSE> + <STOP>
Switch power ON
Switch power OFF to end
player test
1: DispDisplay
Keyboard Control Unit
Digital Board
Display Test
Interactive Test
2: DispLed
LED Test
3: DispKeys
Keyboard Test
4: DispRc
10
11
Remote Control Test
5: AudioMcaSinusOn/Off
6: AudioDsmSawBurst
Sound 1&2 Test
7: VideoColDencOn/Off
8: VideoColDsmOn/Off
9: VideoSigLsiOn/Off
Picture 1&2&3 Test
Basic Engine
Version Number
Tray Test
12: BeSledgeOut/In
13: BeDiscMotorOn/Off
Sledge Test
Disc Motor Test
14: BeFocusOn/Off
15: BeRadialOn/Off
Focus Test
Radial Test
16: BeGroovesIn/Mid/Out
17
Jump Test
Tray Test
18: ReadLog
Error Log & -Bits
Loop Test
2.1 Interactive Tests
2.1.1 Keyboard Control Unit
Display Test
Service Test Level: DispDisplay
By showing a series of test patterns on the local display, the local
display is tested. To step through all different patterns, the user must
either press PLAY (pattern is OK) or PAUSE (pattern was incorrect) to
proceed to the next pattern. The display of patterns is continued
cyclically manner until the user presses NEXT.
Note that a different sample pattern is used here to show all different
display patterns. All other pattern in this document are simplified for
essentials.
If the user presses NEXT before all display patterns are tested, it will
cause an error in the overall result of the System Test.
Service Test Programme
The Service Test Programme is divided into 3 different parts:
– Automatic System Test
– Manual System Test
– PC System Test
The basis of these System Tests are the Service Test Levels, which are
carried out automatically with the respective test or can be called up
manually.
1. Automatic System Test
With the Automatic System Test the hardware of the DVD-Player can
be checked without further equipment.
During the Automatic System Test the Service Test Levels, which are
listed in the table, are called and executed. If the DVD-Player is faulty,
"Error" is shown on the display and the Service Test Levels have to be
executed with the Manual System Test or the PC System Test.
Remark: With the Automatic System Test the A/V-MUX-board is not
tested.
Start of the Automatic System Test
Press 2 keys simultaneously
<OPEN/CLOSE> + <PAUSE>
Switch power ON
SET OK
During the test, the display shows
the number of Levels
which have to be tested.
To exit Automatic Systemtest, switch power OFF
NO
YES
V C D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15 +
-
-
-
-
-
-
-
-
-
-
-
-
-
-
D V D
V C D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15 +
-
-
-
-
-
-
-
-
-
-
-
-
-
-
D V D
V C D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15 +
-
-
-
-
-
-
-
-
-
-
-
-
-
-
D V D
Nucleus
Nucleus
Number
Duration
VideoColDsmOn
37a
3-6s
VideoColDsmOff
37b
10ms
CompDsmDvpAcc
22
100ms
CompDsmDramWrR
25
11s
CompDvpFifoSig
23
100ms
CompLsiAcc
63
100ms
CompLsiDramAcc
65
100ms
CompLsiDramWrR
64
210s
PapDramWrR
13
12s
PapI2cCtrl
15
10ms
PapI2cDenc
19
100ms
PapI2cDisp
17
50ms
PapI2cMca
69
100ms
PapI2cNvram
16
10ms
VideoSigLsiOn
67a
100ms
VideoSigLsiOff
67b
10ms
PapS2bEcho
20
3-8s
PapIntDsm
8
100ms
PapIntDvp
9
100ms
PapIntI2c
7
100ms
PapIntLsi
66
100ms
PapChksEpr1
3
2s
PapChksFl1
5
2s
MAXIMUM DURATION
252s
Number
on
display
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1