OPERATION ________________________________
Connections
Ducted Version Air Exhaust
System
When installing the ducted version, connect
the hood to the chimney using either a flexible
or rigid pipe ø 150 or 120 mm, the choice of
which is left to the installer.
7
To install a ø 120 mm air exhaust connection,
insert the reducer flange 9 on the hood body
outlet.
7
Fix the pipe in position using sufficient pipe
clamps (not supplied).
7
Remove possible charcoal filters.
Recirculation Version Air
Outlet
7
Insert the connection extension pieces later-
ally 14.1 in connection 15.
7
Insert the Connector 15 into the Support
bracket 7.3 and fix it with a screw.
7
Make sure that the outlet of the extension
pieces 14.1 is horizontally and vertically
aligned with the chimney outlets.
7
Connect the air outlet connection 15 to the
hood body outlet using either a flexible or
rigid pipe ø 150 mm, the choice of which is
left to the installer.
7
Ensure that the activated charcoal filters have
been inserted.
Electrical Connection
7
Connect the hood to the mains through a two-
pole switch having a contact gap of at least
3 mm.
7
Remove the grease filters (see paragraph
Maintenance) being sure that the connector
of the feeding cable is correctly inserted in the
socket placed on the side of the fan.