EN / 16
Your house will be flooded if the
water draining hose is dislocated
during water draining. There is also
a risk of burning due to the high
washing temperatures. In order to
prevent such situations and make
sure that the product performs wa-
ter intake and drain processes
without any problem, fix the drain
hose securely.
b. Connect the hose to a minimum height
of 40 cm and a maximum height of 90
cm.
c. If the hose is placed on the floor (or at a
maximum height of 40 cm from the floor)
and then its height is increased, dischar-
ging of water becomes difficult, and
laundry may come out very wet from the
machine. Thus, follow the heights
provided in the figure.
d. To prevent the waste water to go back
into the product again and to ensure
easy drainage, do not immerse the end
of the hose into the waste water or do
not insert it into the drain for more than
15 cm. If it is too long, cut it short.
e. The end of the hose should not be bent,
it should not be stepped on and the
hose must not be pinched between the
drain and the product. Otherwise, water
discharge issues may emerge.
f. If the length of the hose is too short, use
it by adding an original extension hose.
The length of the hose shall not be
longer than 3.2 m. To prevent water
leaks, always secure the connection
between the extension hose and the
draining hose of the product with a suit-
able clamp so that it does not come off
and cause leaks.
4.6 Adjusting the Stands
WARNING
In order to ensure that the product
operates more silently and vibra-
tion-free, it must stand level and
balanced on its feet. Ensure that
the product is balanced by adjust-
ing the feet. Otherwise, the product
may move from its place and cause
crushing, noise and vibration prob-
lems.
To avoid damaging the lock nuts,
do not use any tools to loosen the
nuts.
a. Loosen the lock nuts on the feet by
hand.
b. Adjust the feet until the product stands
level and balanced.
c. Tighten all lock nuts again by hand.
4.7 Electrical Connection
Connect the product to a grounded outlet
protected by a 13 A fuse. Our company
shall not be responsible for the damages
that shall be incurred due to using the
product without grounding according to
local regulations.
• Connection must comply with national
regulations.
• The electrical connection cable infra-
structure of the product must be ad-
equate and suitable for product require-
ments. It is recommended to use a
Ground Fault Circuit Breaker (GFCI).
• Power cable plug must be within easy
reach after installation.