5.3.14. ALARM IN/OUT
The Camera provides one alarm input and one alarm output (N.O. and N.C) to connect alarm devices. With this
function, the Camera will cooperate with alarm systems to catch the event images. For wiring, please refer to
4.2. Camera Overview.
ALARM TYPE:
There are two kinds of alarm types: Normal Open and Normal Close, which are illustrated below. There are four
combinations for the Alarm In/Out setting type including N.O./N.O., N.C./N.O., N.C./N.C. and N.O./N.C., please
select an Alarm In/Out combination that corresponds with your alarm application.
5.3.15. PROTOCOL & ID
Define the protocol and ID you are going to use based on the devices of your surveillance system.
PROTOCOL:
Select a matching Protocol with the correct baud rate to control the Camera via a RS-485 device such as a
keyboard. The Protocol options include Pelco D 2400, Pelco D 4800, Pelco D 9600, Pelco P 2400, Pelco P 4800,
Pelco P 9600 and DSCP 9600.
ID:
Please change the Camera’s ID if there is more than one Camera in the same network. The ID setting range is
from 1 to 255.
NOTE: No two Dome Cameras should be given the same ID, otherwise a communication conflict may occur.
5.3.16. EXIT & SAVE
Select the item <EXIT & SAVE> on the bottom of <MAIN PAGE1> to exit the OSD setup menu.
13
English