USER2:
This mode is the fixed fluorescent light gain
mode and is fitted for indoor lighting
conditions.
- B-GAIN: Adjusts the White Balance for the
colour Blue.
- R-GAIN: Adjusts the White Balance for the
colour Red.
ANTI CR:
With this function you can minimise the problems related to colour rolling caused by the
flickering of fluorescent lights.
MANUAL:
This function allows the white balance to be
adjusted manually.
- LEVEL UP: Keep pressing with the SET
UP key on PUSH ENTER to increase the
white balance level. An increased level
produces a strong blue tone on the screen.
- LEVEL DOWN: Keep pressing with the
SET UP key on PUSH ENTER to decrease
the white balance level. A decreased level
produces a strong red tone on the screen.
- PRESET: When pressing on PRESET with the SET UP key, a predefined setting will
be set.
PUSH LOCK:
This mode is set to the current white balance conditions and keeps its value. Select this
mode and then press the SET UP key. If there is a change in location or light source,
please repeat this procedure.
6.5. WDR
When both low-luminance and high-luminance areas exist in the same picture, this
function can improve the visibility of the entire picture by providing a tone-curve
correction. When selecting
↵
, the following submenu will appear.