background image

20

POWER SUPPLY

_______________________________

Additional information for units sold in the UK.

Units sold in the UK are suitable for operation from a 240V ac, 50Hz mains
supply.
The range of multi-system receivers is built to work in most European coun-
tries. However, the mains plug and socket system for the UK differs from
many European countries.
This appliance has been supplied with a fitted, non-removable, approved
converter plug for use in the UK. This converter plug is fitted with a 5A rated
fuse.

In case this appliance is supplied with a moulded 2-pin Euro plug only,
which is unsuitable for UK operation, this must be cut off and immediately
disposed of. An approved 13A, 3-pin UK plug should then be fitted by a
qualified electrician.

Note:

The severed Euro plug must be destroyed to avoid a possible shock
hazard should it be inserted into a socket elsewhere.

If a non-rewireable 3-pin plug or a rewireable 13A (BS1363) 3-pin plug is
used, it must be fitted with a 5A ASTA or BSI approved BS1362 fuse. If any
other type of plug is used it must be protected by a 5A fuse either in the
plug, or at the distribution board. If this type of plug becomes defective,
ensure that the fuse is removed before disposal, to eliminate potential shock
hazard.

If it is necessary to change the fuse in the non-rewireable plug, the correct
type and rating (5A ASTA or BSI approved BS1362) must be used and the
fuse cover must be refitted. If the fuse cover is lost or damaged, the lead and
plug must not be used until a replacement is obtained. Replacement fuse
covers should be obtained from your dealer.

Important:

The wires in the mains lead are colour coded in accordance with the follo-
wing code:
BLUE – NEUTRAL
BROWN – LIVE
As the colours of the wires in the mains lead of your appliance may not cor-
respond with the coloured marking identifying terminals in your plug, pro-
ceed as follows: 

Connect the BLUE coloured wire to plug terminal marked with the letter “N”
or coloured black.
Connect the BROWN coloured wire to the plug terminal marked with the let-
ter “L” or coloured red.
In no circumstance must any of the wires be connected to the terminal mar-
ked with the letter “E”, earth symbol “

z

”, coloured green, or green & yel-

low.

Replacement mains lead sets can be obtained from your local dealer, or by
contacting Grundig Consumer Relations (01788 570088) 
Moulded 3-pin lead set, suitable for UK use:

Ref: Leadset UK 

8290-991-224

Moulded 2-pin Euro lead set, not suitable for UK use:

Ref: Leadset Euro 

8290-991-316

Summary of Contents for Freaxx RRCD 4202

Page 1: ...RADIO CASSETTE RECORDER WITH CD Freaxx RRCD 4202...

Page 2: ...rrente 67 Informa es 60 Volume som 68 Identifica o de erros 61 Fun o r dio 134 Servi o 69 Seguridad y cuidado 75 Modo CD 70 Vista general 78 Modo casete 72 Alimentaci n de corriente 80 Informaci n gen...

Page 3: ...stains on the surface of the furniture which can be difficult or impossible to remove You will find a symbol similar to the one shown here on the bottom of the device CLASS 1 LASER PRODUCT means that...

Page 4: ...y band switch FM VHF MW medium wave and LW long wave TUNING For tuning to radio stations FM STEREO Stereo indicator lights up when FM stereo is received OVERVIEW ______________________________________...

Page 5: ...cording opens the tape compartment II Pauses recording or playback Indicates the tape direction TAPE DIRECTION Display elements PLAY PAUSE Lights up during CD playback flashes in pause mode REPEAT Lig...

Page 6: ...e the lid 2 Insert six batteries 6 x 1 5 V type IEC LR20 AM1 D size observe the polarity marked on the base of the battery compartment Note Remove the batteries when they are flat or when you know tha...

Page 7: ...lug becomes defective ensure that the fuse is removed before disposal to eliminate potential shock hazard If it is necessary to change the fuse in the non rewireable plug the correct type and rating 5...

Page 8: ...System on or off with UBS Listening with headphones 1 Connect the headphones to the headphones socket y on the left of the device 3 5 mm This automatically switches off the loudspeakers Note Prolonge...

Page 9: ...ion Turn the radio recorder about its own axis to point the antenna Radio reception 1 Switch on the Radio Recorder by setting the CD TAPE OFF RADIO switch to RADIO The ON indicator lights up 2 Select...

Page 10: ...er services of your CD burner software manufacturer or search for information about this in the Internet When you make audio CDs observe all legal guidelines and ensure that the copyrights of third pa...

Page 11: ...display goes out Creating a track memory This function enables you to store up to 20 tracks on the current CD in a cer tain order and then play them back in that sequence The same track may be stored...

Page 12: ...s appears in the display 2 Press PROG Preset position 1 01 PROG flashes in display 3 Start playback of the track memory with II PLAY PAUSE Adding tracks 1 After stopping playback continue pressing PRO...

Page 13: ...g the tape 1 With the tape stopped press 3 or 4 3 fast forwards to the end of the tape 4 rewinds to the beginning of the tape 2 Press when you reach the desired position on the tape Tape recording Era...

Page 14: ...k start the CD playback as usual 4 Once you have reached the desired passage press II PLAY PAUSE 5 To start recording press The CD player starts automatically from the pause mode CD synchro recording...

Page 15: ...and therefore the international safety regulation IEC 60065 Never open the device casing The manufacturer will not accept any liability for damage resulting from improper handling The type plate is lo...

Page 16: ...ischarge Weak radio antenna signal Interference from electrical devices such as televisions video recorders computers neon lamps thermostats or motors The CD is damaged or dirty self recorded CDs may...

Page 17: ...oks 234 N 1401 Ski 47 64 87 82 00 GRUNDIG DANMARK A S Lejrvej 19 DK 3500 V rl se 45 44 48 68 22 GRUNDIG OY Luoteisrinne 5 SF 02271 Espoo 3 58 9 8 04 39 00 GRUNDIG SVENSKA AB Albygatan 109 d Box 4050 S...

Page 18: ...Grundig AG Beuthener Str 41 D 90471 N rnberg http www grundig com 72011 401 9000...

Reviews: