background image

POWER SUPPLY

12

CDP 410/440 page 12

GB

Batteries

• Open the battery compartment and insert as

indicated two alkaline batteries type LR6, AM3,
AA or insert two rechargeable Nickel-Cadmium
batteries .

• Remove the batteries if they are empty or if the

CD player is not to be used for a long time.

The display indicates when the battery voltage is
too low:
• When the indicator 

flashes, the batteries

are getting too weak.

• When 

appears continuously, the battery

voltage is too low and the CD player will soon
shut down.

Note:

The battery supply is switched off when the

DC IN 6.0 V

socket is in use. 

When changing over to battery supply, pull out the
plug from the 

DC IN 6.0 V

socket.

Mains adapter (supplied)

1

Make sure that the local voltage corresponds to
the voltage of the adapter. 

2

Connect the supplied mains adapter (6.0 V/450 mA
Direct Current plus-pole to the centre pin) to the
player's 

DC IN 6.0 V

jack and to the wall outlet.

• Always disconnect the adapter if you are not

using it.

Note:

The CD-player remains connected to the
mains even when it is switched off. 
The unit is only fully isolated from the mains if the
mains adapter is removed from the wall socket.

LINE

OUT

CD IN

(AUX, LINE IN)

LINE OUT

DC IN

-<+

   6.0 V

LINE OUT

Note on Environmental Protection

Do not throw exhausted batteries in
the household refuse. 
Hand over the old batteries to your
dealer or public collecting points when
buying new ones.

DAS

TRACK

MIN

SEC

3 mm

min

Recharging Nickel-Cadmium batteries

(size AA)

Your mains adapter also works as a charger.
This is only possible with 

Ni-Cd 

batteries 

(size AA)

1.2 V/600mAh

Note: 

As a quick reference when buying the Ni-Cd

batteries, be sure that the metal cap on the nega-
tive pole is exposed more than 3 mm as illustrated.
• Charge the batteries prior to first use and also if

the batteries have not been used for a long
period.

• Install the rechargeable batteries in the battery

compartment as described before. 

• Connect the AC adapter to the CD-player and

then to the wall outlet. 

• The batteries should be allowed to recharge for

8 hours for full capacity. 

• The ambient temperature for recharging should

be between 5˚C and 40˚C.

• The player can be operated while the batteries

are being recharged. 

Line out

Reproduction through a stereo system

• Turn down the volume of your stereo system.
• Connect a signal lead to the 

LINE OUT

jack of

the CD player and to the input jacks 

CD IN

,

AUX

(iliary) or 

LINE IN

of the other set (amplifier,

receiver, radio cassette recorder etc.).

• Adjust the sound with the controls of the stereo

system.

Summary of Contents for CDP 410

Page 1: ...PORTABLE CD PLAYER CDP 410 440 ...

Page 2: ...t or devices other than those described and specified in these operating instructions or tampering with the unit in any way can result in dangerous exposure to radiation The display indicates during programming or programme playback during the RANDOM function INTRO during the INTRO function ALL during the REPEAT function repeat all 1 flashing repeat one title LOCK when LOCK is activated and any bu...

Page 3: ... CD data for 10 seconds in advance Activate the DAS memory by pressing the DAS button once The Anti Shock symbol in the display starts filling the display shows for example The state of the DAS symbol in the display changes according to the state of the DAS memory To disable this function press the DAS button once more Note When switching the DAS feature on and off CD play will be delayed or inter...

Page 4: ...E OUT CD IN AUX LINE IN LIN E OU T DC IN 6 0 V LIN E OU T Note on Environmental Protection Do not throw exhausted batteries in the household refuse Hand over the old batteries to your dealer or public collecting points when buying new ones DAS TRACK MIN SEC 3 mm min Recharging Nickel Cadmium batteries size AA Your mains adapter also works as a charger This is only possible with Ni Cd batteries siz...

Page 5: ...utton again you will switch off the set If no button is pressed for 30 seconds the set will switch off automatically The CD player also goes to position STOP by opening the CD lid when the end of the CD is reached if the batteries run down or if the power supply is interrupted Automatic Power Off This CD player is equipped with an automatic power off function In STOP mode the player automatically ...

Page 6: ...D Press the PROG button and the display will flash the letters Select the first desired track using SKIP SEARCH S or T The display shows e g Store this number by pressing the PROG button The display shows Select and store in this way all desired titles P Playing the programme Press PLAY PAUSE 2 Playback starts with the first track of the programme The display shows After the last track playback st...

Page 7: ...lidate the guarantee Problem Possible Cause Remedy No power or no Batteries rech batt CD play start Batteries incorrectly inserted Insert the batteries correctly Display no indication Batteries are empty Change recharge the The LOCK switch is in rechargeable batteries the ON position LOCK switch in position OFF Contact pins are dirty Clean them with a cloth AC power adapter Loose connection Connec...

Page 8: ...GRUNDIG AG D 90762 FÜRTH DEUTSCHLAND 0 1 2 3 4 5 6 7 8 9 72010 761 3000 ...