English (GB)
64
31. Factory settings
*)
Only available if you have fitted an advanced functional module, FM 300.
●
Function is enabled.
❍
Function is disabled.
-
Function is not available.
Settings
TPE3, TPE3 D
TPE2, TPE2 D
Function
description on
page
Setpoint
Auto
●
Operating mode
Normal
Normal
Control mode
AUTO
ADAPT
Const. curve
Date and time
●
*)
●
*)
FLOWLIMIT
❍
-
Automatic Night Setback
❍
-
Temperature influence
❍
-
Buttons on product
●
●
Controller (Controller settings)
Ti
1.0
0.5
Kp
8.0
0.5
Operating range
Min.
25 %
25 %
Max.
100 %
100 %
Ramps
-
❍
Ramp-up
1 second
1 second
Ramp-down
3 seconds
3 seconds
Number (Pump number)
1
1
Radio communication
●
●
Analog input 1
❍
❍
Analog input 2
❍
❍
Analog input 3
❍
❍
Built-in Grundfos sensor
●
-
Grundfos differential pressure sensor
Feedback sensor
-
Grundfos temperature sensor
❍
-
Pt100/1000 input 1
❍
❍
Pt100/1000 input 2
❍
❍
Digital input 1
❍
❍
Digital input 2
❍
❍
Digital in/output 3
❍
❍
Digital in/output 4
❍
❍
Pulse flowmeter
❍
❍
Predefined setpoints
❍
❍
Analog output
❍
❍
External setpoint function
❍
❍
Signal relay 1
❍
❍
Signal relay 2
❍
❍
Limit 1 exceeded
-
❍
Limit 2 exceeded
-
❍
Standstill heating
❍
❍
Motor bearing monitoring
❍
❍
Pump name
Grundfos
Grundfos
Connection code
-
-
Unit configuration
SI
SI