SQE-NE: Only pumps that can be certified as 
uncontaminated, i.e. pumps containing no hazardous 
and/or toxic material, may be returned to Grundfos 
for servicing.

To prevent injury to the health of persons involved 
and to the environment, a document certifying that 
the pump is clean is required.

Grundfos must receive this certificate before the 
product. Otherwise, Grundfos will refuse to accept 
the product for servicing.

Possible costs of returning the pump are paid by the 
customer.

10. Fault finding chart

Warning

Before starting any work on the pump/motor, make sure that the power supply has been 
switched off and that it cannot be accidentally switched on. 

Fault Cause 

Remedy

1.

The pump does 
not run. 

a)

The fuses in the electric 
installation are blown. 

Replace the blown fuses. If the new ones 
blow too, the electric installation and the 
submersible drop cable should be 
checked. 

b)

The ELCB or the voltage-operated 
ELCB has tripped out. 

Cut in the circuit breaker. 

c)

No power supply. 

Contact the power supply authorities. 

d)

The motor protection has cut off 
the power supply due to overload. 

Check whether the motor/pump is blocked. 

e)

The pump/submersible drop cable 
is defective. 

Repair/replace the pump/cable.

f)

Overvoltage or undervoltage has 
occurred.

Check the power supply.

2.

The pump runs 
but gives no 
water. 

a)

The discharge valve is closed. 

Open the valve. 

b)

No water or too low water level in 
borehole. 

See item 3 a).

c)

The non-return valve is stuck in its 
closed position. 

Pull out the pump and clean or replace the 
valve. 

d)

The suction strainer is choked up. 

Pull out the pump and clean the strainer. 

e)

The pump is defective. 

Repair/replace the pump.

Summary of Contents for SQE-NE Series

Page 1: ...on 12 6 1 General 12 6 2 Assembly of pump part and motor 12 6 3 Removal of non return valve 12 6 4 Fitting the cable plug to the motor 13 6 5 Fitting the cable guard 13 6 6 Cable sizing 14 6 7 Fitting...

Page 2: ...ator As a minimum the generator output must be equal to the motor P1 kW 10 Starting current The motor starting current is equal to the highest value stated on the motor nameplate Power factor PF 1 Mot...

Page 3: ...ng a screwdriver or a similar tool 4 Inject motor liquid into the motor with a filling syringe or the like 5 To allow possible air to escape move the motor from side to side 6 Refit the filling plug a...

Page 4: ...arked with the following symbol Supply voltage 1 x 200 240 V 10 6 50 60 Hz PE The current consumption can only be measured by means of a true RMS instrument If other instruments are used the value mea...

Page 5: ...be used on the clamping faces of the pump part See fig 6 Fig 6 When pump part and motor have been assembled correctly there must not be a clearance between pump part and motor 6 3 Removal of non retur...

Page 6: ...earance between the motor and the cable plug 6 5 Fitting the cable guard To fit the cable guard proceed as follows 1 Make sure that the submersible drop cable lies flat in the cable guard 2 Place the...

Page 7: ...Fitting the submersible drop cable It is recommended to join the submersible drop cable and the motor cable by means of a Grundfos cable termination kit type KM For larger cross sections please contac...

Page 8: ...lation depths Maximum installation depth below the static water level 150 metres See fig 11 Minimum installation depths below the dynamic water level Vertical installation During start up and operatio...

Page 9: ...switch and diaphragm tank during starting will be lower than the pump cut in pressure set on the pressure switch pcut in This lower pressure is called minimum pressure pmin pmin is equal to the desir...

Page 10: ...ce tools are available from Grundfos The Grundfos Service Manual is available on request The pumps can be serviced at a Grundfos service centre 9 1 Contaminated pumps If Grundfos is requested to servi...

Page 11: ...n the electric installation are blown Replace the blown fuses If the new ones blow too the electric installation and the submersible drop cable should be checked b The ELCB or the voltage operated ELC...

Page 12: ...e is defective Replace the riser pipe i Undervoltage has occurred Check the power supply 4 Frequent starts and stops a The differential of the pressure switch between the start and stop pressures is t...

Page 13: ...d neutral Connect the voltmeter to the terminals at the connection The voltage should when the motor is loaded be within the range specified in section 5 Electrical connection Large variations in supp...

Reviews: