10. Fault finding chart

Fault

Cause

Remedy

1.

The pump does 
not run. 

a) The fuses in the electric installation 

are blown. 

Replace the fuses. If the new ones blow 
too, the electric installation and the supply 
cable should be checked.

b) The ELCB or the voltage-operated 

ELCB has tripped out. 

Cut in the circuit breaker.

c) No electricity supply. 

Contact the electricity supply authorities. 

d) The motor protection has cut off 

the electricity supply due to over-
load.

Check whether the motor/pump is blocked. 

e) The pump/supply cable is defec-

tive. 

Repair or replace the pump/cable.

f) The float switch is in dry-running 

position.

Check the water level and the float switch 
for free movability.

g) The pump is blocked.

Check and clean the pump.

2.

The pump runs but 
gives no water. 

a) The discharge valve is closed. 

Open the valve.

b) No water or too low water level in 

well. 

Increase the installation depth of the pump 
(maximum 20 metres). Reduce the pump 
performance or replace the pump by a 
smaller model to obtain a smaller capacity.

c) The non-return valve is stuck in its 

closed position. 

Pull out the pump and clean or replace the 
valve.

d) The suction strainer is choked up. 

Pull out the pump and clean the suction 
strainer and the impeller, if necessary, see 
section 

9.1 Cleaning the pump suction 

strainer

.

e) The pump is defective. 

Repair or replace the pump.

f) The pump has not been primed 

(pump with base plate).

Prime the pump, see section 

7. Start-up

.

3.

The pump runs at 
reduced capacity. 

a) The drawdown is larger than antici-

pated. 

Increase the installation depth of the pump 
(maximum 20 metres). Reduce the pump 
performance or replace the pump by a 
smaller model to obtain a smaller capacity.

b) The valves in the discharge pipe 

are partly closed/blocked. 

Check and clean or replace the valves, if 
necessary.

c) The discharge pipe is partly 

blocked by impurities. 

Clean or replace the discharge pipe.

d) The non-return valve in the dis-

charge pipe is partly blocked. 

Clean or replace the valve.

e) The pump and discharge pipe are 

partly blocked by impurities. 

Pull out the pump. Check and clean or re-
place the pump, if necessary. Clean the 
pipes.

f) The pump is defective. 

Repair or replace the pump.

g) Leakage in the pipework. 

Check and repair the pipework.

h) The discharge pipe is defective. 

Replace the discharge pipe. 

i) Undervoltage has occurred.

Check the electricity supply.

Summary of Contents for SPO 3-40A

Page 1: ...SPO GRUNDFOS INSTRUCTIONS Installation and operating instructions...

Page 2: ...e com as Directivas do Conselho das Comunidades Europeias relativas aproxima o das legisla es dos Estados Membros respei tantes M quinas 98 37 CE Norma utilizada EN ISO 12100 Compatibilidade electroma...

Page 3: ...nte electrice destinate utiliz rii ntre limite exacte de tensiune 73 23 CEE 95 Standarde aplicate EN 60335 1 1994 i EN 60335 2 41 1996 Grundfos SPO 98 37 EO EN ISO 12100 89 336 E O EN 61000 6 2 EN 610...

Page 4: ...ndarts EN ISO 12100 Elektromagn tisk savienojam ba 89 336 EEK Piem rotie standarti EN 61000 6 2 un EN 61000 6 3 Elektriskais apr kojums kas paredz ts lieto anai zin mu sprieguma robe v rt bu ietvaros...

Page 5: ...tsinstruktion 60 Asennus ja k ytt ohjeet 66 Monterings og driftsinstruktion 72 Instrukcja monta u i eksploatacji 78 84 Szerel si s zemeltet si utas t s 92 Navodilo za monta o in obratovanje 98 Monta n...

Page 6: ...lower or lift the pump by means of the supply cable 3 2 Storage The pump must be stored indoors in a dry position Note Pumps with base plate must be drained before storage 4 Technical data See pump n...

Page 7: ...t contain sand or solid sediment Installation in well Install the pump so that the pump inlet is at least 1 metre above the bottom of the well Installation in tank Place the pump on the bottom of the...

Page 8: ...mp on a plane surface 2 Start the pump and stop it immediately 3 Observe the movement jerk of the pump when started seen from the top of the pump The direction of rotation is correct clockwise if the...

Page 9: ...ids other than clean water it should be flushed through with clean water immediately after use 8 1 Periods of inactivity If the pump is taken out of operation for a long pe riod it should be drained P...

Page 10: ...Pull out the pump and clean or replace the valve d The suction strainer is choked up Pull out the pump and clean the suction strainer and the impeller if necessary see section 9 1 Cleaning the pump su...

Page 11: ...itch to ensure suitable time between the cutting in and cutting out of the pump see section 7 1 Adjustment of float switch c The non return valve is leaking or stuck half open Clean or replace the non...

Page 12: ...TM02 6643 4403 104 115 67 75 73a 50 84 66 5a 6 64 4 49 4 64 49 64c 105a 62 37 155 193 105 69a 69 20 182a 182 20a 16 160 14 13 156a 37b 173 158 154 37c 48 47 172 152 153 151 37d 155a 193a 161 157 176a...

Page 13: ...644 4403 18 28 36a 67 75 73a 37a 56 66 5a 6 64 4 49 4 64 49 64c 105a 62 37 155 193 105 69a 69 20 20a 16 160 14 13 26 156a 37b 173 158 154 37c 48 47 172 152 153 151 37d 155a 193a 161 157 176a 181 18 10...

Page 14: ...lefax 81 53 484 1014 Korea GRUNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia...

Page 15: ...www grundfos com 96506912 1005 185 Repl 96506912 0503 Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence...

Reviews: