English (GB)
19
10. Starting up the product after
standstill
1. Check that the pump is not blocked by following
the instructions in section
2. If the pump has been drained, it must be filled
with liquid before startup. See section
3. Start up the pump. Follow the instructions in
section
.
4. The pump will remember the controller settings
even if it is turned off.
10.1 Deblocking the pump
The end cover incorporates a plug which can be
removed by means of a suitable tool. This makes it
possible to deblock the pump shaft if it has seized up
as a result of inactivity.
Fig. 22
Deblocking the pump
11. Taking the product out of
operation
If the pump is taken out of operation for a period of
time, for example during the winter, it must be
disconnected from the power supply and placed in a
dry location.
Proceed as follows:
1. Stop the pump by means of the on/off button
.
2. Disconnect the power supply.
3. Open a tap to release the pressure in the pipe
system.
4. Close the isolating valves and/or drain the pipes.
5. Gradually loosen the priming plug to release the
pressure in the pump.
6. Remove the drain plug to drain the pump. See
7. We recommend to store the pump indoors in a
dry location. Due to humidity, the disconnected
pump must not be left outside for a longer period
of time.
Fig. 23
Draining the pump
DANGER
Electric shock
Death or serious personal injury
- Switch off the power supply before
starting any work on the product. Make
sure that the power supply cannot be
accidentally switched on.
TM
06 42
02 161
5
T
M
06
42
03
16
15