TM072373
Commissioning for operation with liquid
concentrate
Commissioning must be done by certified
service persons.
Wear personal protective equipment.
Observe the chemical manufacturer's safe-
ty data sheets (SDS) and safety instruc-
tions of the used chemicals.
Make sure that all electrical, hydraulic and
mechanical installation is done correctly
and all system components are ready for
operation. The system must be stopped
and control mode must be "Local".
Some pre-assembled mechanical and hy-
draulic connections in the system are loos-
ened for transport. Make sure all connec-
tions are tightened before commissioning.
Do not step on the system. The system is
not designed to carry the weight of a per-
son.
Make sure that the liquid-concentrate line
is connected with a foot valve and installed
with flooded suction to avoid dry-running of
the pump.
Safety instructions for the operation of Polydos
systems
The system must only be operated by au-
thorised and qualified persons.
Wipe up spilled water, polymer or polymer
solution immediately to avoid slipping haz-
ard.
Make sure that you have a secure foothold
when filling the dry-material feeder. For
safety reasons Grundfos strongly recom-
mends the installation of an automatic
powder conveying system.
Do not step on the system. The system is
not designed to carry the weight of a per-
son.
WARNING
Chemical hazard
Death or serious personal injury
‐
Wear personal protective equipment.
‐
Observe the chemical manufacturer's
safety data sheets (SDS) and safety in-
structions of the used chemi-
cals. The required actions are descri-
bed in the safety data sheet. Check the
safety data sheet regularly and re-
place, if necessary, as the hazard po-
tential of a substance can be re-evalu-
ated at any time based on new find-
ings. The operating company is re-
sponsible for ensuring that the safety
data sheets are available and that they
are kept up to date, as well as for pro-
ducing an associated hazard assess-
ment for the workstations affected.
Dry-material feeder calibration
CAUTION
Crushing of hands
Minor or moderate personal injury
‐
After removing the dissolving hopper,
do not reach into the dosing screw.
The dosing screw starts running when
you switch on the dry-material feeder.
6
English (GB)
Summary of Contents for PD412