23. Check condition and cleanliness of the split coupling pieces.
TM080413
24. Make sure that:
• The split coupling pieces engage with shaft keys.
• The coupling rests against the fork tool flap.
TM080414
25. Keep the gap between the coupling pieces equal.
If you do not have an equal gap, loosen the side with
the smaller gap and tighten the side with the larger
gap until both sides are equal.
TM080415
26. Tighten by hand, and check the coupling gap.
TM080416
27. Remove the fork tool.
TM080417
28. Cross-tighten coupling screws.
For the required torque, see Torques table.
TM080418
20