Enclosure class
•
Single-phase pumps: IP 55 (IEC 34-5).
•
Three-phase pumps, 0.75-7.5 kW: IP 55 (IEC 34-5).
•
Three-phase pumps, 11-22 kW: IP 55 (IEC 34-5).
Insulation class
F (IEC 85).
Ambient temperature
During operation:
•
Min – 20 °C
•
Max + 40 °C. without derating
During storage/transport:
•
– 30 °C to + 60 °C (0.37-7.5 kW)
•
– 25 °C to + 70 °C (11-22 kW).
Relative air humidity
Maximum 95 %.
Sound pressure level
Single-phase pumps:
<70 dB(A).
Three-phase pumps:
Motor
[kW]
Speed stated on nameplate
[min
-1
]
Sound pressure level
[dB(A)]
2-pole
4-pole
0.55
1400-1500
47
1700-1800
52
0.75
1400-1500
47
1700-1800
52
2800-3000
60
3400-3600
65
1.1
1400-1500
49
1700-1800
53
2800-3000
60
3400-3600
65
1.5
1400-1500
53
1700-1800
57
2800-3000
65
3400-3600
70
2.2
1400-1500
50
1700-1800
52
2800-3000
65
3400-3600
70
3.0
1400-1500
55
1700-1800
60
2800-3000
65
3400-3600
70
4.0
1400-1500
58
1700-1800
63
2800-3000
70
3400-3600
75
5.5
1400-1500
57
1700-1800
59
2800-3000
75
3400-3600
80
7.5
1400-1500
59
1700-1800
61
2800-3000
67
3400-3600
72
11
1400-1500
63
1700-1800
64
2800-3000
64
3400-3600
68
15
1400-1500
65
1700-1800
66
2800-3000
65
3400-3600
68
18.5
1400-1500
69
1700-1800
72
2800-3000
69
3400-3600
70
22
1400-1500
–
1700-1800
–
2800-3000
67
3400-3600
70