9.2 Fault indications
The fault indication below can be read by means of the number in
brackets, as text or as status indications on the control panel,
depending on the equipment available.
Grundfos Eye
Condition/cause
Remedy
Two opposite red indicator lights
flashing simultaneously.
External fault (3)
An external signal has reported an
"External fault" to the digital input set up
for this function.
Check the parameter or the unit reporting the
external fault. Correct the fault.
Too many restarts (4)
The pump has restarted to many times in
connection with a fault that forced the
pump to stop and restart automatically.
a) Check the warning and alarm log for faults that
caused to many restarts.
b) Replace the pump if the fault cannot be found.
Overvoltage (32)
Supply voltage to the pump too high.
a) Check that the power supply is within the
specified range.
Undervoltage (40)
Supply voltage to the pump too low.
a) Check that the power supply is within the
specified range.
Overload (49)
The motor is overloaded and has
automatically reduced the speed and thus
the pump performance.
a) Check that the viscosity and temperature of the
pump liquid is within the limits for the pump. If
not, change the properties of the liquid.
b) Dismantle the pump, and remove any foreign
matter or impurities preventing the pump from
rotating.
c) If none of the above causes are present,
replace the pump.
Blocked pump (51)
The pump is blocked.
a) Dismantle the pump, and remove any foreign
matter or impurities preventing the pump from
rotating.
One yellow indicator light permanently
on.
Pump communication fault (10)
Communication fault between this pump
and the other pumps of the multipump
system.
a) Check that all pumps of the multipump system
have been correctly set up.
Forced pumping (29)
Other pumps or sources force flow
through the pump even if the pump is
stopped.
a) Check the system for defective non-return
valves and replace, if necessary. Check the
system for correct position of non-return valves,
etc.
Dry running (56, 57)
No water at the pump inlet or the water
contains too much air.
a) Prime and vent the pump before a new start-up.
Check that the pump is operating correctly. If
not, replace the pump.
Internal fault (72, 83, 85, 155, 157, 163)
Internal fault in the pump electronics.
a) Replace the functional module, power module
or terminal box.