Make sure that the electrical installation supports the rated
current [A] of the product. See the product's nameplate.
3.3.1 Connecting products with a plug
WARNING
Electric shock
Death or serious personal injury
‐
Make sure that the power-supply plug delivered with
the product is in compliance with local regulations.
‐
The plug must have the same protective earth (PE)
connection system as the power outlet. If not, use a
suitable adapter if allowed by local regulations.
Do not turn on the power supply until the pump has been
filled with liquid.
1.
Switch off the power supply to the power socket.
2.
Connect the plug to the power socket.
3.3.2 Connecting products without a plug
WARNING
Electric shock
Death or serious personal injury
‐
Power supply cables without a plug must be connected
to a supply disconnecting device incorporated in the
fixed wiring according to the local wiring rules.
Do not turn on the power supply until the pump has been
filled with liquid.
If the product is delivered with a cable but without a plug, connect
the cable to the external main switch or attach a plug.
Connecting the cable to an external main switch
1.
Strip the cable.
2.
Thread each individual wire to the correct terminal in the
external main switch.
Wiring a plug
1.
Strip the cable.
2.
Loosen the two screws holding the cable clamp and pull the
cable through.
3.
Thread each individual wire to the correct terminal.
4.
Tighten the terminal screws and the cable clamp screw. Make
sure not to overtighten the cable clamp screw.
1
2
3
4
TM072505
Fig.
Example, plug wiring
Pos.
Description
1
E: Earth, yellow and green wire
2
N: Neutral, blue wire
3
L: Live, brown wire
4
Cable clamp
Related information
3.3.3 Connecting products without a cable
3.3.3 Connecting products without a cable
WARNING
Electric shock
Death or serious personal injury
‐
Power supply cables without a plug must be connected
to a supply disconnecting device incorporated in the
fixed wiring according to the local wiring rules.
Do not turn on the power supply until the pump has been
filled with liquid.
If the product is delivered without a cable, please connect the pump
to the power supply using one of the following cable types:
Pump model
Recommended cable type
JP 3-42 and JP 4-47
H05 RN-F
JP 4-54 and JP 5-48
H07 RN-F
Do as follows to connect the cable to the pump:
1.
Remove the top cover on the motor by loosening the screws.
2.
Locate the power-supply terminal and cable clamp inside the
terminal box.
3.
Loosen the cable clamp.
4.
Pull one end of the cable through the cable gland located on
the side of the terminal box.
9