background image

English (GB)

  Installation and operating instructions

Original installation and operating instructions

Table of contents

1.

General information . . . . . . . . . . . . . . . . . . . . . . . . 5

1.1

Target group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

1.2

Hazard statements . . . . . . . . . . . . . . . . . . . . . . . . . . 5

1.3

Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

2.

Receiving the product . . . . . . . . . . . . . . . . . . . . . . . 5

2.1

Inspecting the product. . . . . . . . . . . . . . . . . . . . . . . . 5

2.2

Scope of delivery, JP . . . . . . . . . . . . . . . . . . . . . . . . 5

2.3

Scope of delivery, JP Booster . . . . . . . . . . . . . . . . . . . 6

3.

Installing the product . . . . . . . . . . . . . . . . . . . . . . . 6

3.1

Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3.2

Mechanical installation . . . . . . . . . . . . . . . . . . . . . . . 6

3.3

Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . . 8

4.

Startup of the product . . . . . . . . . . . . . . . . . . . . . . 10

4.1

Priming the product . . . . . . . . . . . . . . . . . . . . . . . . 11

4.2

Starting up the product . . . . . . . . . . . . . . . . . . . . . . 11

5.

Product introduction. . . . . . . . . . . . . . . . . . . . . . . 11

5.1

Product overview, JP . . . . . . . . . . . . . . . . . . . . . . . 12

5.2

Product overview, JP Booster . . . . . . . . . . . . . . . . . . 12

5.3

Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

5.4

Pumped liquids . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

5.5

Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

6.

Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

6.1

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

6.2

Maintaining the pressure tank . . . . . . . . . . . . . . . . . . 13

6.3

Service kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

7.

Taking the product out of operation . . . . . . . . . . . . . 14

7.1

Draining JP and JP PT-V . . . . . . . . . . . . . . . . . . . . . 14

7.2

Draining JP PT-H. . . . . . . . . . . . . . . . . . . . . . . . . . 14

7.3

Storage of the product. . . . . . . . . . . . . . . . . . . . . . . 14

7.4

Frost protection . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

8.

Fault finding the product . . . . . . . . . . . . . . . . . . . . 14

8.1

The pump does not start . . . . . . . . . . . . . . . . . . . . . 15

8.2

The pump stops unexpectedly during operation and
starts again after a while . . . . . . . . . . . . . . . . . . . . . 15

8.3

The pump runs, but does not deliver the expected
amount of water . . . . . . . . . . . . . . . . . . . . . . . . . . 15

8.4

Fault finding boosters with a pressure manager . . . . . . . 15

8.5

Fault finding boosters with a pressure tank . . . . . . . . . . 16

9.

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

9.1

Operating conditions. . . . . . . . . . . . . . . . . . . . . . . . 17

9.2

Head and flow rate. . . . . . . . . . . . . . . . . . . . . . . . . 17

9.3

Inlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

9.4

Miscellaneous data . . . . . . . . . . . . . . . . . . . . . . . . 17

10.

Disposing of the product . . . . . . . . . . . . . . . . . . . . 17

1. General information

This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction
concerning use of the appliance in a safe way and
understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children without
supervision.

Read this document before you install the product.
Installation and operation must comply with local
regulations and accepted codes of good practice.

1.1 Target group

These installation and operating instructions are intended for
professional as well as non-professional users.

1.2 Hazard statements

The symbols and hazard statements below may appear in Grundfos
installation and operating instructions, safety instructions and
service instructions.

DANGER

Indicates a hazardous situation which, if not avoided, will
result in death or serious personal injury.

WARNING

Indicates a hazardous situation which, if not avoided,
could result in death or serious personal injury.

CAUTION

Indicates a hazardous situation which, if not avoided,
could result in minor or moderate personal injury.

The hazard statements are structured in the following way:

SIGNAL WORD
Description of the hazard

Consequence of ignoring the warning

Action to avoid the hazard.

1.3 Notes

The symbols and notes below may appear in Grundfos installation
and operating instructions, safety instructions and service
instructions. 

Observe these instructions for explosion-proof products.

A blue or grey circle with a white graphical symbol
indicates that an action must be taken.

A red or grey circle with a diagonal bar, possibly with a
black graphical symbol, indicates that an action must not
be taken or must be stopped.

If these instructions are not observed, it may result in
malfunction or damage to the equipment.

Tips and advice that make the work easier.

2. Receiving the product

2.1 Inspecting the product

On receipt of the product, do the following:
1.

Check that the product is as ordered.
If the product is not as ordered, contact the supplier.

2.

Make sure that the supply voltage and frequency correspond to
the values stated on the product nameplate.

Related information

5.5.1 Nameplate example for JP and JP Booster

2.2 Scope of delivery, JP

The box contains the following items:

1 Grundfos JP pump

1 lifting-handle kit

1 quick guide

1 safety instructions booklet.

5

English (GB)

Summary of Contents for JP 3-42

Page 1: ...JP and JP Booster Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Page 2: ...his document before you install the product Installation and operation must comply with local regulations and accepted codes of good practice 1 1 Target group These installation and operating instruct...

Page 3: ...40 55 C 50 Hz 60 Hz JP 3 42 ON 20 min OFF 40 min ON 20 min OFF 40 min JP 4 47 ON 15 min OFF 45 min ON 10 min OFF 50 min JP 4 54 ON 20 min OFF 40 min ON 20 min OFF 40 min JP 5 48 ON 20 min OFF 40 min...

Page 4: ...esigned for the maximum pump pressure The maximum inlet pressure depends on the head at the actual duty point The sum of the inlet pressure and the head must not exceed the maximum system pressure We...

Page 5: ...Electrical connection WARNING Electric shock Death or serious personal injury Switch off the power supply before you start any work on the product Make sure that the power supply cannot be switched on...

Page 6: ...correct terminal in the external main switch Wiring a plug 1 Strip the cable 2 Loosen the two screws holding the cable clamp and pull the cable through 3 Thread each individual wire to the correct ter...

Page 7: ...ependent motor protection If the pump is running without water is blocked or otherwise overloaded the built in thermal switch will cut out When the motor has cooled sufficiently it will restart automa...

Page 8: ...leakage from the shaft seal of up to 10 ml per day or 8 to 10 drops per hour may occur Under normal conditions the leaking liquid will evaporate As a result no leakage will be detected When the pump...

Page 9: ...water CAUTION Impurities in the water Minor or moderate personal injury Do not use the product for drinking water The AISI 316 variant of the JP pump is especially suitable for pool cleaning applicat...

Page 10: ...us personal injury Make sure that the product has only been used for water If the product has been used for pumping aggressive liquids flush the system with clean water before you start work on the pr...

Page 11: ...72420 Related information 7 Taking the product out of operation 7 2 Draining JP PT H To drain JP Booster with a horizontal pressure tank do as follows 1 Drain the pump by removing the drain plug 2 Uns...

Page 12: ...at a high pressure Remedy Clean the pipe or open the isolating valves if any Cause The pump is not filled with water Remedy Prime the pump Cause The inlet pipe is blocked by impurities Remedy Clean t...

Page 13: ...e sure that the built in circuit breaker of the pump is switched off Cause The motor protection of the pump has tripped due to overload Remedy Make sure the motor or pump is not blocked Cause The pump...

Page 14: ...P 5 48 1 0 bar 0 10 MPa 9 4 Miscellaneous data Cut in pressure Preset cut in pressure start pressure JP PM 1 5 bar JP PT V 2 2 bar JP PT H 2 2 bar Min max storage temperature 20 70 C 10 Disposing of t...

Page 15: ...9 3 3 22 4 24 4 1 24 4 2 24 5 25 5 1 JP 25 5 2 JP Booster 26 5 3 26 5 4 26 5 5 26 6 27 6 1 27 6 2 27 6 3 27 7 27 7 1 JP JP PT V 28 7 2 JP PT H 28 7 3 28 7 4 28 8 28 8 1 29 8 2 29 8 3 29 8 4 29 8 5 e 3...

Page 16: ...1 1 2 3 JP Booster 1 Grundfos JP Booster 1 1 3 3 1 3 1 2 3 1 1 3 1 2 55 C 40 C 40 55 C 20 40 S3 40 55 C 50 Hz 60 Hz JP 3 42 20 40 20 40 JP 4 47 15 45 10 50 JP 4 54 20 40 20 40 JP 5 48 20 40 30 30 3 1...

Page 17: ...F G TM072477 JP PT H JP mm JP PT H mm F 47 265 G 110 230 3 2 2 JP 2 1 1x 2x 1 1 TM072418 2 4 1 2 3 TM072419 4 TM072480 3 2 3 1 10 m 4 m 1 2 3 4 5 5 TM064532 3 2 3 1 3 2 3 2 20 BG...

Page 18: ...rea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Tel 82 2 5317 600 Fax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznesa centrs Augusta Deglava iel 60 LV 1...

Page 19: ...emarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2018 Grundfos...

Reviews: