6.2 Applications
The lifting station is designed for pumping grey and
black wastewater from family houses and
commercial buildings where the liquid cannot be led
directly to the sewer due to lack of a natural
downward slope.
6.3 Pumped liquids
Unilift CC, Unilift KP, Unilift APB
Grey wastewater, that is domestic wastewater
without toilet discharge.
Unilift AP50B may be used for black wastewater, that
is domestic wastewater with toilet discharge, in
countries allowing outlet pipes of DN 50 for black
wastewater without using a grinder pump.
SEG
Grey and black wastewater, that is domestic
wastewater with toilet discharge.
The SEG pump has a grinder system.
Surface water must not be discharged into a lifting
station inside the building.
6.4 Automatic operation
The lifting station is designed to operate
automatically according to the liquid level in the tank.
You can set the lifting station to automatic operation
in two ways. Equip the lifting station either with float
switches, fitted directly on the pumps, or with a level
sensor tube and a controller.
6.5 Identification
6.5.1 Type key
6.5.2 Nameplate
Fig. 24
Nameplate, lifting station
6.6 Diaphragm pump
We recommend that you connect a diaphragm pump
to the tank. It is a positive displacement pump which
can be operated manually. It can be used to drain the
tank before service or during power cuts. The tank
has a DN 40 outlet for the pump.
6.7 Level sensor tube
The level sensor is an accessory, which works
together with a controller LC 220 or LC 221.
The level sensor tube is connected to a
piezoresistive level sensor in the controller via the
level sensor hose.
The rising liquid level compresses the air inside the
level sensor tube and hose, and the piezoresistive
sensor transforms the changing pressure into an
analog signal. The controller uses the analog signal
to start and stop the pump and to indicate high-level
alarm.
UNOLIFT 270. 40. CC
Model
Unolift: one pump
Duolift: two pumps
Tank volume
[litres]
270
540
Outlet
DN 40
Pump
CC
KP
APB, APB
SEG
T
M
04
7
6
3
9
22
10
Pos.
Description
1
Type designation
2
Product number
3
Production code (year and week)
4-8
-
9
CE mark
10
-
11
Serial number
12-14
-
15
Maximum liquid temperature [°C]
16
Maximum ambient temperature [°C]
17
Weight [kg]
18
-
19
Reference number for the declaration of
performance
20
Notified body
Typ
Prod.-Nr.
P. c.
f
Hz
Serial no.
Phases
U
V
A
kW
G
kg
m
m
98127055
0197
I
1/1
P
1
Q
max
H
min
H
max
T
Med
max
T
Amb
max
m /h
3
C
C
Made in Germany
96075419
DK - 8850 Bjerringbro, Denmark
1
2
3
4
5
6
10
11
12
13
14
15
16
17
18
20
19
7
8
9
Summary of Contents for DUOLIFT Series
Page 1: ...UNOLIFT DUOLIFT Installation and operating instructions GRUNDFOS INSTRUCTIONS...
Page 2: ...2...
Page 30: ...BG 30 3 3 20 25 40 100 3 4 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 3 5 3 6 3 TM06 5780 0116...
Page 31: ...BG 31 3 7 100 40 6 1 1 3 2 1 7 1 2 3 4 100 40 TM06 5851 0216...
Page 35: ...BG 35 12 Unilift CC KP TM05 9630 3913...
Page 47: ...BG 47 12 ct 1 a 1 2 7 1 b 2 a 1 2 7 1 3 a 7 1 b 13 c 9 10 4 a 6 mm 5 a...
Page 48: ...BG 48 13 1 2 Grundfos...
Page 49: ...BG 49...
Page 80: ...Deutsch DE 80 Abb 12 Unilift CC KP TM05 9630 3913...
Page 143: ...Espa ol ES 143 Fig 12 Unilift CC KP TM05 9630 3913...
Page 205: ...GR 205 3 3 20 25 40 100 3 4 E 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 3 5 3 6 3 TM06 5780 0116...
Page 207: ...GR 207 3 10 PVC 63 mm 75 mm 75 mm 1451 3 11 3 7 1 2 96615831 3 7 TM06 5859 0216...
Page 210: ...GR 210 12 Unilift CC KP TM05 9630 3913...
Page 222: ...GR 222 12 1 a 1 2 7 1 b 2 a 1 2 7 1 3 a 7 1 b 13 c 9 10 4 a 6mm 5 a...
Page 223: ...GR 223 13 1 2 Grundfos...
Page 234: ...Magyar HU 234 12 bra Unilift CC KP TM05 9630 3913...
Page 256: ...Italiano IT 256 Fig 12 Unilift CC KP TM05 9630 3913...
Page 366: ...Portugu s PT 366 Fig 12 Unilift CC KP TM05 9630 3913...
Page 459: ...CN 459 12 13 1 2 1 a 1 2 7 1 b 2 a 1 2 7 1 3 a 7 1 b 13 c 9 10 4 a 6 mm 5 a...
Page 460: ...Appendix 460 Appendix 1 Fig 1 Unolift 270 Duolift 270 TM06 1067 1514...
Page 461: ...Appendix 461 Fig 2 Duolift 540 TM06 1066 1514...