English (GB)
25
Set analog scaling in the "
Operation
" menu
Analog scaling can also be modified after a security
prompt directly in the "
Operation
" menu. This is how
the dosing flow is directly modified for the current
flow input value.
Fig. 21
Set analog scaling ("
Operation
" menu)
6.4.4
Batch (pulse-based)
In this operation mode, the pump doses the
set batch volume in the set dosing time (t
1
).
A batch is dosed with each incoming pulse.
Fig. 22
Batch (pulse-based)
The setting range depends on the pump type:
*
Thanks to the digital motor control, dosing
quantities with a resolution of up to 1/8 of the
dosing stroke volume can be dosed.
The batch volume (e.g. 75 ml) is set in the "
Setup
>
Batch volume
" menu. The minimum dosing time
required for this (e.g. 36 seconds) is displayed and
can be increased.
Fig. 23
Batch
mode
Signals received during a batch process or an
interruption (e.g. alarm,
External stop
) will be
ignored. If the pump is restarted following an
interruption, the next batch volume is dosed on the
next incoming pulse.
Fig. 24
Batch
mode
In the "
Operation
" menu, the total batch volume (e.g.
75 ml) and the remaining batch volume still to be
dosed (e.g. 43 ml) are shown in the display.
Caution
Please observe that changes also have
a direct effect on point I
2
/Q
2
(see fig. 21)!
T
M
0
4
1
1
32
20
10
T
M
0
4
1
1
05
20
10
Type
Setting range per batch
from [ml]
to [l]
Resolution*
[ml]
DDA 7.5-16
0.74
999
0.0925
DDA 12-10
1.45
999
0.1813
DDA 17-7
1.55
999
0.1938
DDA 30-4
3.10
999
0.3875
4
0
20
100
0
Q [%]
I [mA]
new
actual mA
(I
2
/Q
2
)
(I
1
/Q
1
)
(I
2
/Q
2
)
Pulse
Batch volume
Pulse
Time
t
1
t
1
TM
04 1
1
34
1
11
0
TM0
4
1
1
35
11
1
0
Setup
Batch
>
75.0ml
36.0
Input
>
Off
>
Operation mode
Batch volume
Dosing time
[s]
Analog output
SlowMode
Operation
75.0
ml
Batch
43.0ml