background image

 

 

General notes 

Our systems have to be installed by an 
approved sanitary or heating company. 

Prior to installation, check the compo-
nents for shipping damage. 

The devices must be protected against 
frost and must not be installed near heat 
sources which radiate a lot of heat. 

  

Attention

: Do not clean the filter with 

cleaning agents that contain alcohol or 
solvents! 

 

 

 

In case of drinking water that contains a 
lot of coarse dirt, a coarse filter must be 
installed upstream. 

 

1 Application 

The FS-B filters are designed for the 
filtration of drinking water. The filters are 
not suited for circulation water that has 
been treated with chemicals. Further-
more, it is neither suited for oils, greas-
es, solvents, soaps and other lubricating 
media nor for the separation of water-
soluble materials. The filters may be 
used in the pressure and negative pres-
sure range. 

 

 

2 Technical specifications 

Fine filter 

FS-B 

Connection diameter 

1“ 

1¼“ 

1½“  

2“ 

Nominal connection diameter  [DN]

25 

32 

40 

50 

Nominal flow at  

p 0.2(0.5) bar 

[m³/h] 3.7(6,0)

4.0(6,2) 11.1(19,9) 13.9(23,3)

Filter fineness 

[µm]

80  

Diameter of upper/ lower 
outlet 

[µm]

140/80 

Nominal pressure 

PN 16 

Total height  

[mm]

265 

508 

Replacement height for 
filter element 

[mm]

150 390 

Length with/without screw 
connections 

[mm] 182/100 191/100 283/160 277/160

Empty 

weight 

[kg]

1.2 1.4 3.7 4.4 

DVGW registration mark 

NW-9301BT0200 

Max. water / ambient 
temperature 

[°C]

30/40 

Order no. 

101 170 101 175  101 180  101 185

 

3 Installation 

requirements 

Please observe local installation guidelines 
and general regulations as well as tech-
nical specifications. 

The installation site must be frost-proof 
and must ensure the protection of the 
filter against chemicals, dyes, solvents, 
vapours and direct sunlight.  

 

 

Observe flow direction (

 indicated on 

the housing)! Install voltage-free. The 
installation site must be frost-proof. 

The filter should be installed in equally 
dimensioned pipes according to its 
nominal diameter. 

 
 

4  Scope of  

delivery 

  Filter with protective cover and built-

in maintenance indicator. 

  Screw connections with seals made 

of LD-PE.  

  Filter element 80 µm 

 Operation 

manual 

 
 

5 Installation 
 

As per DIN EN 806-2 and DIN 1988-200 
the FS-B filter has to be installed in the 
cold water pipe downstream of the water 
meter and upstream of the distribution 
pipes respectively upstream of the de-
vices to be protected. Install shut-off 
valves upstream and downstream of the 
filter (refer to fig. 1). The filter is suited 
for horizontal installation only. 

 
 

 

Fig. 1: Installation drawing FS-B front view  

 

 

 

1

Union nut 

2

Insert 

3

Flat seal 

Fig. 2: View FS-B 

 

 

 

 
 

6 Start-up

 

After completion of the installation, put 
the filter into operation by opening the 
shut-off valves. Then de-aerate the 
piping via the nearest screw connection. 

Leakage test 

A leakage test must be performed on the 
filter directly after installation and after 
each time maintenance work was per-
formed. In order to check the filter for 
tightness, the highest pressure admissi-
ble must be applied. 

 

7 Inspection / 
 Maintenance 

According to the DIN Standard EN 806-
5, the operator must 

inspect

 the filters 

every two months (functional inspection). 
During the inspection, the filter element 
must be checked for contamination and 
be replaced, if necessary (contamination 
and/or increased differential pressure). 
Check for tightness.  

Furthermore, 

maintenance

 has to be 

performed by the operator or the installa-
tion company every six months.  

 

Warning!

 According to DIN EN 806-5  

the filter element must be replaced for 
hygienic reasons every 6 months. Fur-
thermore, we recommend replacing the 
seal of the protective cylinder every 2 
years using a set of seals. 

 

 

Replacement of 
filter element 

 

 

Fig.3: Replacement of 
filter element

 

How to proceed 

  Place a bucket beneath the filter.  

  Close the shut-off valves. 

  Depressurize the pipe.  

  Manually unscrew the filter cylinder. 

  Remove the dirty filter element from 

the supporting fabric and replace by 
new filter element. For hygienic rea-
sons, do not touch the new filter ele-
ment with bare hands.  
Hygienic filter replacement: 
Open the foil and push the filter ele-
ment including the foil over the support-
ing fabric, pull off the foil without touch-
ing the filter element. (see fig. 3) 

  Check that the sealing surfaces as 

well as the O-ring are clean and 
manually screw on the filter cylinder 
to the stop. 

  Start up as described in point 6. 

Edited by: KO

N

S

-fger-mrie G

:\BA-101196-IN

TER

_

FS-B.D

O

C

 

 

Reviews: