background image

12

• 

Always wear protection gear like safety goggles, gloves, 
apron, and ear plugs while operating the pump

• 

Never let any body part come in front of, or in contact with 
the control outlet

• 

Always cut off air supply after use, so that media cannot leak 
incase any of the pump component fails

• 

Before switching the air supply on, check hoses for sign of 
wear, leak or loose fittings. Replace as necessary

• 

Do not smoke near the pump. Do not use the pump near a 
source of spark / open flames

• 

When changing the working fluid, at least 1 litre of new fluid 
should be discarded to avoid mixing of fluids

• 

Pump should NOT be operated for more than 4 hrs 
continuously

• 

Pump must be supplied with CLEAN & DRY compressed air 
via an FRL unit

• 

Before attempting any maintenance or repair of this product, 
disconnect air supply and then squeeze control valve trigger 
to release fluid pressure

• 

Use only genuine factory parts for repair

• 

In case of accident, immediately seek medical attention. Do 
not try to treat the injury yourself

Groz Engineering Tools (P) Ltd.
Groz Net Industries

Village Kherki Daula, National Highway-8
Gurgaon-122001, Haryana, INDIA
TEL  +91.124.282.7700 / 221.4050
FAX  +91.124.2827986 / 221.4224
FAX (USA)  +1.509.271.7848
FAX (UK)     +44.870.121.1854

E-MAIL  [email protected]
URL       www.groz-tools.com

The Groz name, Groz logo and the         mark are 
trademarks of Groz Engineering Tools (P) Ltd. India

MODEL

BGRP/15

BGRP/30

BGRP/50

Bucket Capacity

15 Kg / 1.8 Gal / 33 lbs.

30 Kg / 3.5 Gal / 60 lbs.

50 Kg / 6 Gal / 110 lbs.

Suction Tube Length

17.32” (440 mm)

17.32” (440 mm)

28.74” (730 mm)

Suction Tube Dia.

1.18” (30 mm)

Flow Rate 

1.10 Kg / min. (2.42 lbs / min) 

Working Pressure

10 BAR (150 PSI)

Maximum Outlet Pressure

500 BAR (7500 PSI)

Air Inlet Connection

¼” (F) 

Pump Outlet Connection

¼” (F) 

Air Consumption

230 LPM (61 GPM)

Hose Length*

7’ (84”)

Noise Level

81 db

SPECIFICATIONS

WETTED COMPONENTS

Steel, Brass, Aluminium, & Polyurethane

RECOMMENDED USE 

With light and self collapsing grease up to NLGI No. 2

* IT MAY VARY FROM ONE MODEL TO ANOTHER

Summary of Contents for BGRP Series

Page 1: ...hassle free operation Pump dispenses Grease at pressures upto 50 times the Air inlet pressure Designed to work in tough conditions Ideal for use in Industry workshop farm construction or as part of th...

Page 2: ...ting inside the pump cylinder The grease is discharged with pressure from the outlet located at bottom of Air Motor into the delivery hose 1 Grease Pump Assembly 2 Drum Cover 3 Rubber Lined Follower P...

Page 3: ...D downwards The air under the Piston C is evacuated through passage B past the Slider Valve F and out at arrow G The Piston approaches bottom dead centre and Piston rod D makes contact with the Slide...

Page 4: ...s provided along with the drum cover An FRL Filter Regulator Lubricator unit must be used in the Air supply before it is connected to the pump Set the regulator to 6 BAR 90 PSI or any required inlet p...

Page 5: ...e upper two Slotted Spring Pins 44 unscrew the Extension Rod 46 and then Connector 45 6 Assemble by following the steps 1 5 in reverse order taking care of the points below 1 Remove Bend Pipe 1 by ope...

Page 6: ...48 5 1 8 2 9 10 7 12 13 19 2 18 6 24 4 20 21 22 21 14 19 23 26 28 30 31 32 33 16 34 18 16 17 35 36 11 40 42 41 44 43 45 44 50 54 57 58 59 63 Replace Component No 51 52 53 55 as a SET 49 Slotted side...

Page 7: ...usher Spring 2 18 Pusher Nut 2 19 Pusher Button 2 20 Circlip 1 21 Filter B 2 22 O Ring BS121 1 23 Exhaust Valve 1 24 Paper Seal 1 25 Seat 1 26 Slider Guide 1 27 Nylon slider 1 28 Clip 1 29 Self Tappin...

Page 8: ...Cover 1 67 Hose 1 68 Z Swivel 1 69 Grease Control Valve 1 REFERENCE NO DESCRIPTION QUANTITY 45 Connector 1 46 Extension Rod 1 47 Steel Ball 7 32 2 48 Non Return Spring 2 49 Valve 1 50 O ring BS812 2...

Page 9: ...er locating the faulty section check the respective Piston Plunger the associated washers seals for any overlap or wear tear Replace the defective parts from Repair Kit 4 Ensure to replace the moving...

Page 10: ...BGRP15 Follower Plate BGRP30 Follower Plate BGRP50 65 DC BGRP 15 DC GP1 BL DC GP2 BL Drum Cover BGRP15 Drum Cover BGRP30 Drum Cover BGRP50 66 HOSE GRP 84 B HOSE GRP 84 N Hose BSP Threads Hose NPT Thr...

Page 11: ...M4 RP Self Tapping Screw 29 2 ORG BS129 O Ring 31 1 ORG BS614 O Ring 37 1 GUD SEL RP Slider Guide 38 1 SEAL RP Seal 39 4 SU SEL RP Seal Support 40 1 ROD CNR S RP Connecting Rod 43 1 SSP 3 0 6 15 3 Slo...

Page 12: ...factory parts for repair In case of accident immediately seek medical attention Do not try to treat the injury yourself Groz Engineering Tools P Ltd Groz Net Industries Village Kherki Daula National H...

Reviews: