Fig
5
.
12
Fig
5
.
13
Fig
5
.
14
Connecting
Cable
6
6
.
1 Connection on AC side
•
"
OFF”
also
disconnect
AC
switch
,
otherwise
the
high
voltage
from
inverter
may
cause
life
risk
.
•Only
trained
authorized
electrical
technician
can
do
the
electric
connection
also
please
follow
the
connection
procedures
in
this
manual
along
with
local
country's
regulations
.
•High
voltage
may
cause
electric
shocks
and
serious
injury
please
do
not
touch
the
inverter
.
•Please
do
not
store
inverter
in
area
with
flammable
and
explosive material.
Before
electrical
connection
,
please
ensure
the
inverter
DC
switch
is
at
•
with
other
inverters
.
•It
is
forbidden
to
add
load
between
inverter
and
breaker
.
Each
inverter
must
install
one
AC
breaker
,
AC
breaker
is
forbidden
to
share
Preparation
before
connection
:
1>Disconnect
inverter
DC
switch
and
AC
breaker
or
switch.
2>When
you
lock
the
AC
cable's
screw,
the
torque
force
should
be
100kgf·cm.
When you lock the cover screw, the torque force
should
be 35kgf·cm.
3>Measure
the
grid
voltage
and
frequency
,
please
refer
to
chapter
10
.
AC
breaker
specification
:
Inverter
model
Breaker
model
MAX
50KTL3
LV
100A
/
400Vac
MAX
60KTL3
LV
125A
/
400Vac
MAX 70KTL3
LV
160A
/
400Vac
MAX
80KTL3
LV
160A
/
400Vac
MAX
60KTL3
MV
100A
/
500Vac
MAX
70KTL3
MV
125A
/
500Vac
MAX
80-100KTL3
MV
160A
/
500Vac
15
16
DANGER
WARNING
Decisive Voltage Class (DVC) indicated for ports
Port Name
Class
AC
DC
DRMS
RS485&USB
C
C
A
A