Grove Audio GMS-742a MIDI Preliminary Operation Manual Download Page 8

Copyright 2022 – Grove Audio LLC 

All rights reserved 

 

performed enables it. Holding the C3 key down enables zero calibration. Holding the C5 
key down enables the span calibration. Then, by pressing the next lower or upper 
adjacent key, the value can be

 decremented

 or 

incremented

. On the computer keyboard, 

the enable key for zero calibration would be the “Z” key which corresponds to C3. This 
key is at the end of a row and does not have an adjacent lower key. This problem can be 
resolved by shifting the C3 key up an octave to the “,” key by first pressing function key 
F5. In MIDIOx the function keys shift the keyboard up and down by octave increments. 
The default, with C4 on the “,” key is obtained by pressing F6. 

Once the keyboard has been shifted by pressing the F5, then zero calibration can use 
the “,” key to enable, the “M” key to decrement the value and the “.” key to increment 
the value. 

Next adjust the span of the scale. First, press the F6 key to return the keyboard to the 
default position. The span enable is C5, the “I” key. In the keyboard default position, 
there are keys on both sides for decrement and increment.  

By repeating the zero and span calibration several times, it will be possible to achieve 
proper scaling between the two calibration points. To check the calibration, return to 
the run mode and try different Cs to be sure that they fall on integer volt values within 
+- 2 mV (approximately plus or minus two cents).  

Setting up and using MIDIOX with external controller 

An external keyboard controller can be routed to the converter module to perform 
calibration by using MIDIOX. Open the OPTIONS/MIDI Devices tab. Click the name of the 
converter module under MIDI Outputs to cause it to appear under Port Mapping. If the 
external controller was shown under MIDI Inputs and the “Automatically attach inputs 
to outputs during selection” was checked, the external keyboard should be added as a 
source under the module name in the Port Mapping list. If the external controller is 
attached to and detected by the computer after MIDIOX is started, MIDIOX will need to 
be restarted in order to be aware of the new USB devices. 

To select the zero calibrate enable, press and hold the C3 on the keyboard. If the 
keyboard has a limited range such as a typical 37 key midi controller where there is no 
key to the left of C3, use the octave shift keys on the controller to move the C3 key 
upscale an octave. When setting the span on C5, it may be necessary to move the 
keyboard range downscale again using the octave shift key. 

Frequency calibration method 

The frequency calibration method can be used to correct for anomalies in the scaling of a VCO. The 
relationship between the midi to cv converter is relative and the goal of the method is to bring the 
oscillator frequencies into correspondence with the correct MIDI note that is being played. It has the 
further advantage in that it does not require a high precision DC voltmeter. As long as a means of 
measuring frequency (pitch) is available, this method can be used. This may be a frequency counter, a 
tuner, or a pitch reading application for a cellphone.  

Summary of Contents for GMS-742a MIDI

Page 1: ...Copyright 2022 Grove Audio LLC All rights reserved 1 GMS 742a MIDI to CV CONVERTER PRELIMINARY OPERATION MANUAL APRIL 17 2022 Grove Audio LLC Copyright 2022 All Rights Reserved...

Page 2: ...hannel will produce the voltage equivalant of the MIDI velocity value one gate channel will produce a gate signal for the duration of the MIDI note on to note off time and one gate channel will produc...

Page 3: ...Note CV Gate Ch 2 C2 C5 Note CV Gate Common MIDI Channel 10 2 Ch Independent Legato On Split Keyboard Ch 1 C0 B1 Note CV Gate Ch 2 C2 C5 Note CV Gate Common MIDI Channel 15 Channel Calibration Mode 1...

Page 4: ...roximately two seconds until the Gate 1 LED starts to flash This indicates that the module is in the programming mode By briefly pressing the toggle switch to the right and releasing it the program gr...

Page 5: ...ck div 6 Zero volts at C2 7 1 8 clock div default 7 Zero volts at C1 default Q104 mode 8 1 8 dotted clock div 8 Disable Pitchbend for mode 7 8 default 9 1 4 clock div 9 Enable Pitchbend for mode 7 8 1...

Page 6: ...le switch to be high from the time the RUN realtime message or MIDI note command is received until the STOP realtime message or MIDI note command is received The output can be set to be either a level...

Page 7: ...acy meter will work but a 5 digit DVM is preferred The current calibration points are between C3 and C5 The default values for these calibration points for the 5 Volt are 1 0000 Volts Calibration valu...

Page 8: ...h external controller An external keyboard controller can be routed to the converter module to perform calibration by using MIDIOX Open the OPTIONS MIDI Devices tab Click the name of the converter mod...

Page 9: ...ng calibration The module can store and recall up to 16 sets of calibration tables including zero and span calibration values for the 5 V 5V range The set of tables stored in the default location will...

Page 10: ...Connect a USB type A cable from the host computer and plug the miniB end of the cable into the USB connector on the module There may be some preliminary communication and installation of drivers Even...

Reviews: