background image

Service manual and spare parts list 

549225

Drying  cabinet with 8 kg cloth capacity

www.groupdynamics-laundry.com 

[email protected]

Summary of Contents for DC 8

Page 1: ...Service manual and spare parts list 549225 Drying cabinet with 8 kg cloth capacity www groupdynamics laundry com sales groupdynamics lv ...

Page 2: ...2 2011 Thank you for choosing our drying cabinet We hope that it will be of great use for you www groupdynamics laundry com sales groupdynamics lv ...

Page 3: ...nsions 4 Technical information 5 Main control board 5 Service menu 5 Parameter list 6 Explanation of parameters 7 Error codes 8 Spare parts list 9 Cabinet 9 Top 10 Electrical drawing 11 www groupdynamics laundry com sales groupdynamics lv ...

Page 4: ...4 2011 Dimensions Specification 200 1870 1200 242 469 1855 1453 640 A B A Electrical connection B Exhaust www groupdynamics laundry com sales groupdynamics lv ...

Page 5: ...control board s parameters The following pages describe how to adjust the parameters Service menu Activate the service menu To enter the service menu press both left arrow buttons in about 5 seconds The LCD display shows the software version installed on the control board Push the START button 5 times continuously to enter the pa rameter list Navigate in the service menu To browse in the parameter...

Page 6: ...3 00 DEF TIME 0 00 MAX TID 00 40 DELAY START ON OFF OFF AUTOPROG OFF 1 9 2 PR1 TEMP MIN MED MAX MAX PR1 HU STOP 0 995 65 PR2 TEMP MIN MED MAX MAX PR2 HU STOP 0 995 490 HYST TEMP 0 20 10 COOL DOWN 0 00 0 20 00 15 SHOW TEMP HU ON OFF OFF SHOW LOGO ON OFF ON SOUND ON OFF ON STANDBY ON OFF ON LIGHT TIME 0 00 0 30 00 10 PAUSE TIME 0 00 0 30 00 10 COIN ON OFF OFF SIGNAL TYPE PLS N 0 N O WORK TIME 000000...

Page 7: ... MED TEMP and MAX TEMP PR HU STOP HU STOP affects the automatic drying function Can be chan ged if needed If the value of HU STOP is decreased the drying time is prolonged for the automatic programme HYST TEMP It controls the hysteresis The drying cabinet is preset to 10ºC When the working temperature is attained and the heating ele ments are turned off it will be a delay When the temperature hits...

Page 8: ...w button The programme goes automatically to the next level after 30 seconds 1 Fans connected to FAN1 2 External fan connected to FAN2 optional 3 Heating on 4 All segments on LCD display are lit and the background light flashes 5 The temperature sensor shows current temperature 6 The humidity sensor shows current air humidity CLEAR E CODE Is used to erase an e code in the display after the problem...

Page 9: ...ight 6 TS 61081 Lamp Bulb 7 70107001 Door switch 8 TS 61089 Magnet list 9 0110151 2 Display control board 10 TS 61090 Cover glass 11 0110152 Keypad 12 011053 Sticker user manual 13 TS 61091 Hanging frame 14 TS 61093 Hanging level 4 arms 15 TS 61092 Hanging level 5 arms 16 TS 61094 Foot 17 TS 61097 Protection plate Detailed view A www groupdynamics laundry com sales groupdynamics lv ...

Page 10: ... 2 Temperature sensor 4 TS 61026 Over heat protection 120ºC 5 504142 Relay LC1 D12P7 230 V 6 TS 61082 Disturbance filter 7 0110154 2 Humidity sensor 8 TS 61083 Condenser 9 0110150 2 Main control board 10 TS 61098 Service door upper Top www groupdynamics laundry com sales groupdynamics lv ...

Page 11: ...UMIDITY SENSOR MICRO SWITCH LIGHT MICRO SWITCH RELAY FAN RELAY HEAT M1 FAN MOTOR LAMP 15 L1 X1 X2 KK1 13 14 13 14 B2 17 NTC1 16 B1 13 14 H1 1 2 DOOR NTC1 HEATER MAIN FAN1 CN2 FAN2 K1 3 4 5 6 1 2 2 7 8 I0528105 2 3 400V N 50 60Hz L3 L2 L1 N 1 N L1 M1 L1 M2 N KF1 KF2 K2 1 2 9 18 T1 120 C 2 1 6 5 o K1 A2 A1 11 10 K3 A1 A2 K2 A1 A2 12 www groupdynamics laundry com sales groupdynamics lv ...

Page 12: ...2011 09 08 www groupdynamics laundry com sales groupdynamics lv ...

Reviews: