9
Specifications
Model
GZNA 1.2500DXII
RMS Power @ 4
Ω
CEA Standard CEA-2006-A
850W
(1% THD+N)
1100W
(10% THD+N)
RMS Power @ 2
Ω
CEA Standard CEA-2006-A
1500W
(1% THD+N)
2000W
(10% THD+N)
RMS Power @ 1
Ω
CEA Standard CEA-2006-A
2300W
(1% THD+N)
3000W
(10% THD+N)
RMS Power @ 2
Ω
Linkmode
CEA Standard CEA-2006-A
1 x 4600W
(1% THD+N)
1 x 6000W
(10% THD+N)
Damping factor
> 180
Signal to noise Ratio
> 90 dB
Lowpass
30 – 250 Hz (24 dB)
Bandpass
5 Hz – 250 Hz (24 dB)
Subsonic filter
5 Hz – 50 Hz (24 dB)
Bass boost
0 ~ +9 dB
Bass boost Frequency
30 Hz ~ 80 Hz
Phase shift
0 – 180°
Frequency response
5 Hz – 250 Hz
Efficiency @ 4
Ω
~ 80 %
Input sensitivity
200 mV – 9 V
(± 5%)
THD
< 0,50 %
Bass remote
9
Fuse
External ANL-fuse 200A
(included in delivery)
Dimensions
W x H x L mm
305 x 62 x 450
Dimensions
W x H x L inch
12 x 2.44 x 17.7“
10
Trouble shooting guide
Symptoms
Check Points
Cure
No sound
Is the POWER LED illuminated?
Check fuses in amplifier.
Be sure remote lead is connected.
Check signal leads.
Check again control.
Check tuner/deck volume level.
Is the diagnostic LED illuminated?
Check for speaker short or
amplifier overheating
Amp not switching on
No power to the amplifier
Check power wire or connections
No power to remote wire with
receiver on
Check connections to radio
No sound in one channel
Check speaker leads
Inspect for short circuit or an open
connection
Check audio leads
Reverse left and right RCA inputs
to determine if it is occurring
before the amp
Amp turning off at medium /
high volume
Check speaker load impedance
Be sure proper speaker load
impedance recommendations are
observed
(If you use an ohm meter to
check speaker resistance, please
remember that DC resistance and
AC impedance may not be the
same.)
Protection LED is on
Temperature shut down
Turn radio volume down
Speaker wires short
Separate speaker wires and
insulate