Ground Zero NUCLEAR GZNA 2800XII Owner'S Manual Download Page 5

 
 

 

 

 

Trimode operation  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connecting the speaker for trimode operation - notes 

 
TRI MODE operation output allows a subwoofer to be operated in mono mode while the main speakers are 

playing in stereo. Leave the crossover switch on “Full” position. 
 
Use 100 volt, non-polar capacitors for a high pass crossover to filter out low frequencies and Air- core or  
Ferrit- ore coils with a minimum diameter of 1 mm / 0.039” for the lowpass crossover to filter out high 

frequencies.

 

 
The capacitor and inductor values as written in the below table. The front and rear channels of this amplifier get 

this capability. Only the rear left and right channels are shown on the following pictures. 
 
 

Values for 6dB passive crossover 

 

 

 
 

 

 

 

 

Frequency 

Inductor 

Capacitor 

80 Hz 

7,5 mH 

470 uF 

100 Hz 

6,5 mH 

330 uF 

120 Hz 

5,5 mH 

370 uF 

150 Hz 

4 mH 

220 uF 

 
 

 

10 

 

 

Specifications 

 

 
 

 

 

 

 

 

 
 

 

 

 

 

 
 

 

 

 

 
 

 

 

 

 

 
 

 

 

 

 

 
 

 

 

 

 

 

Model 

GZNA 2800XII 

RMS Power @ 4 

 

CEA Standard CEA-2006-A                    

 

2 x 430W 

(1% THD+N) 

2 x 520W

 (10% THD+N)

 

RMS Power @ 2 

 

CEA Standard CEA-2006-A                    

 

2 x 800W 

(1% THD+N) 

2 x 950W 

(10% THD+N)

 

RMS Power @ 1 

 

CEA Standard CEA-2006-A                    

 

2 x 1200W 

(1% THD+N) 

2 x 1400W 

(10% THD+N)

 

RMS Power @ 4

 bridged  

CEA Standard CEA-2006-A                    

 

1 x 1600W 

(1% THD+N) 

1 x 1900W 

(10% THD+N)

 

RMS Power @ 2

 bridged  

CEA Standard CEA-2006-A                    

 

1 x 2400W 

(1% THD+N) 

1 x 2800W 

(10% THD+N)

 

Damping factor 

> 150 

Signal to noise Ratio 

> 90 dB 

Lowpass 

30 – 400 Hz / 300 – 4000 Hz 

Highpass 

5 – 400 Hz / 50 – 4000 Hz 

Bandpass  

5 Hz – 4000 Hz 

Subsonic filter 

5 Hz – 4000 Hz 

Bass boost  

0 ~ +12 dB 

Bass boost frequency 

30 Hz ~ 80 Hz 

Phase shift  

0 – 180° 

Frequency response 

10 Hz – 38 KHz 

(± 1 dB) 

Efficiency @ 4 

 

~ 80 % 

Input sensitivity 

200 mV – 9 V 

(± 5%) 

Channel separation 

50 dB 

THD 

< 0,10 % 

Bass remote 

9

 

At Lowpass- operation 

Fuse 

External ANL-fuse 200A  

(included in delivery) 

Dimensions

W x H x L mm 

305 x 62 x 600 

Dimensions 

W x H x L inch 

12 x 2.44 x 23.62“ 

Summary of Contents for NUCLEAR GZNA 2800XII

Page 1: ...product Features 1 Ohm stable stereo 0 5 Ohm stable at music operation 2 Ohm stable bridged 1 Ohm stable at music operation Dual Mosfet power supply SMD Technology Power Protection indicator Variable 12dB Bass Boost High pass filter Subsonic filter with 1 10 switch variable to 4000Hz Low pass filter with 1 10 switch variable to 4000Hz Variable phase shift 0 180 Adjustable input sensitivity Soft de...

Page 2: ...vels may impair your ability to hear external sounds such as horns warning signals or emergency vehicles thus constituting to a potential traffic hazard In the interest of safety Consumer Electronics recommends listening at lower volume levels while driving 4 Planning your system Before beginning the installation consider the following a If you plan to expand your system by adding other components...

Page 3: ...5 Power connection 6 Controls and functions ...

Page 4: ...uced In this adjustment the Highpass Subsonic is also activated FULL All frequencies will be reproduced HIGH Subsonic Only middle and high frequencies over 5Hz 4000Hz will be reproduced 10 Low pass controller For subwoofer and Kickwoofer operation Only frequencies from 30Hz to 4000Hz will be reproduced depending on the lowpass filter controller position Set the filter switch to LOW position Adjust...

Page 5: ...5 5 mH 370 uF 150 Hz 4 mH 220 uF 10 Specifications Model GZNA 2800XII RMS Power 4 Ω CEA Standard CEA 2006 A 2 x 430W 1 THD N 2 x 520W 10 THD N RMS Power 2 Ω CEA Standard CEA 2006 A 2 x 800W 1 THD N 2 x 950W 10 THD N RMS Power 1 Ω CEA Standard CEA 2006 A 2 x 1200W 1 THD N 2 x 1400W 10 THD N RMS Power 4Ω bridged CEA Standard CEA 2006 A 1 x 1600W 1 THD N 1 x 1900W 10 THD N RMS Power 2Ω bridged CEA St...

Page 6: ... of the original purchasing invoice showing the purchasing date and a detailed description of the failure Failure caused by overload misuse or by using the product for competition purpose are not covered by the warranty De Garantie bepalingen van alle door ground zero geleverde producten is volgens wettelijke bepalingen geregeld Een retourzending kan alleen na duidelijke afspraak en in de originel...

Reviews: