HAY BED PUMP:
MAKE SURE POWER AND GROUND WIRES ARE HOOKED UP CORRECTLY THROUGH BREAKER TO
THE MOTOR.
IF ONE FUNCTION WORKS OR SOUNDS LIKE MOTOR IS BUILDING PRESSURE BUT NOTHING IS
HAPPENING, CHECK SOLENOIDS. TAKE OFF THE POST, PLACE SCREWDRIVER IN AND PRESS
FUNCTIONS. IF IT MAGNETIZES, SOLENOIDS ARE GOOD.
MUST PURGE AIR FROM THE HYDRAULIC SYSTEM UPON START UP BY CYLCING THE HAY BED TO
A POSITION ALLOWING THE PUMP TO PUSH AIR OUT OF THE SYSTEM FOR 15-30 SECONDS.
IF JERKING AS IT LETS BALE DOWN, MAY NEED TO ADJUST THE REGULATOR VALVE (ARM BED)
AFTER INSPECTING CORRECT FLOW INSTALLED CORRECTLY. TURN ALL THE WAY OFF AND
ADJUST IN .25 TURN INTERVALS UNTIL OPERATION IS NORMAL SET LOCK NUT, COMES FROM
THE FACTORY PRESET ½ TURN FROM OFF.
IF ARMS ARE NOT SYCHRONIZING OPEN OR ONE WON’T OPEN AS FAR AS SUPPOSE TO, MAKE
SURE CYLINDERS ARE INSTALLED ON THE RIGHT SIDES AND HOSES ARE HOOKED UP
ACCORDING TO THE DIAGRAM.
TOOLBOXES:
IF STANDING WATER IN TOOLBOXES, DEALERS ARE AUTHORIZED TO DRILL TWO .6” DIAMETER
HOLES IN EACH BOX.
FEEDERS:
COUNTER:
MAKE SURE WIRED INTO TERMINALS 2 & 6, FOR BACKLIGHT TO WORK 5VDC HAS
TO BE APPLIED TO TERMINAL 5 AND GROUND SUPPLY TO TERMINAL 6. IF COUNTER NOT
COUNTING, TAKE A PAPER CLIP AND HAVE IT TOUCH TERMINAL 2 & 6. IF MAKES A COUNT,
PROBLEM NOT WITH COUNTER.
MAGNET:
CAN WAVE MAGNET IN FRONT OF SENSOR TO SEE IF SENSOR IS BAD OR IF THE
SENSOR NEEDS TO BE MOVED CLOSER TO THE MAGNET. IF FEED IS KNOCKING THE MAGNET
LOOSE, PLEASE PURCHASE A RUBBER SEAL KIT ON PAGE 16.
ADJUST AUGER COVER UP OR DOWN IN ¼” INTERVALS UNTIL FEEDER FLOW RATE IS ACHIEVED.
FOR ANY OTHER TROUBLESHOOTING PROBLEMS, WE
REQUIRE A MINIMUM OF 4 PICTURES EITHER TEXT OR EMAIL.