![Grosvenor Sateon Advance 2 Door Blade Installation Manual Download Page 3](http://html1.mh-extra.com/html/grosvenor/sateon-advance-2-door-blade/sateon-advance-2-door-blade_installation-manual_2269893003.webp)
GND
In +
+12 V
+5 V
GND
RS485 A
RS485 B
Clock/D1
Data/D0
Valid
Beeper
Tamper
+12 V
Sounder
GND
REX
GND
Sensor
Lock +
GND
BGU
+12 V
+5 V
GND
RS485 A
RS485 B
Clock/D1
Data/D0
Valid
Beeper
Tamper
+12 V
Sounder
GND
REX
GND
Sensor
Lock +
GND
BGU
sateon
2 DOOR BLADE
Aux In +
Out ±
Return ±
Aux In +
GND
Out ±
Return ±
GND
0V
+12-24V
IN
IN
IN
Door/
Reader
1
Door/
Reader
2
I/O 1
I/O 2
External
power
+12 V
+5 V
GND
RS485 A
RS485 B
Clock/D1
Data/D0
Valid
Beeper
Tamper
+12 V
+5 V
GND
RS485 A
RS485 B
Clock/D1
Data/D0
Valid
Beeper
Tamper
HID Reader connections
Sateon Reader connections
Wiegand keypads can be
supported using the same
wiring.
+
_
Exit switch
Door sensor
+12 V
Sounder
GND
REX
GND
Sensor
Contact Only (no fault detection)
+
_
Door sensor
Exit switch
1K
1K
+12 V
Sounder
GND
REX
GND
Sensor
Contact Only (short/open circuit)
+
_
Door sensor
A1
Exit switch
1K
1K
2K2
Door sensor
A2
+12 V
Sounder
GND
REX
GND
Sensor
Contact Only (short/open circuit fault detect)
Resistors should be fi tted
as close as possible to the
door sensor.
Reader Connections
Door Connections
Reader and Door Connections
Resistors should be fi tted
as close as possible to the
door sensor.
Page 3