background image

1

English

Application 

Operation is possible in conjunction with:

- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters  

Operation with low-pressure storage heaters 
(displacement water heaters) is not possible.

Specifications 

x

Max. flow                     approx. 50 L/min or 13.2 gpm

x

Flow pressure   
-  min.                                       

7.25 psi

-  recommended                         

14.5 - 72.5 psi

-  greater than 72.5 psi, fit with pressure  reducing 

valves

x

Max. operating pressure                      

145 psi

x

Test pressure                                

232 psi

x

Temperature    
- max. (hot water inlet)                      

176 

q

F

x

 Water connection   

cold - Right hand

hot - Left hand

Notes

- An access panel must be provided for access to 

hose connections.

- Major pressure differences between cold and hot 

water supply should be avoided.

Installation

Layout dimensions to establish proper clearances, see 
dimensional drawing on fold-out page I.

Flush pipes thoroughly!

Side valves

x

Valve marked with "L" (left close) on the top edge of 
the cartridge (A) with blue tape should be mounted 
on the right (cold water) side.

x

Valve marked with "R" (right close) on the top edge 
of the cartridge (A) with red tape should be mounted 
on the left (hot water) side.

1. Screw the mounting set (B) to the bottom of the 

thread of the side valve (C), see fold-out page III, 
fig. [1].

Make sure that the rubber washer (B1) is on the top 
of the fiber washer (B2).

2. Insert the side valve (C) through the basin hole from 

below.

3. Place the escutcheon O-ring (D1) on the basin and 

screw down the escutcheon (D) until it stops.

4. Screw the cap (E) down to the escutcheon (D). 

5. Secure the handle (F) or lever (G) to the stem of the 

ceramic cartridge (A).
It is recommended that the lever handle (G) be 
installed so they point away from the spout when in 
the off position.

If the gap between the handle and the cap is ex-
cessive, back off the cap (E) and the escutcheon (D) 
to minimize the gap.

6. Tighten the mounting set (B) from below to secure 

the valve.

Spout, see fig. [2].
1. Place the O-ring (I1) and the escutcheon (H1) on the 

basin.

2. Insert the spout (H) through the escutcheon (H1) 

and basin.

3. Secure the spout with the mounting set (I). 
4. Install the diverter (J) to the spout.

Connect faucet, see fig. [3].

Install elbows (K) onto the diverter (L).
Connect the side valves to the water supply. Insure the 
supplied washers are used for all connections.

The hot water supply should be connected on the left 
side valve (marked red) and the cold water supply to 
the right valve (marked blue).

Open cold and hot water supply and check 
connections for leakage.

Maintenance

Inspect and clean all parts, replace as necessary and 
grease with special grease (order no. 18 012).

Shut off cold and hot water supply.

I. Ceramic cartridge, see fold-out page II.
1. Remove handle (45 776, 45 790) and cap.
2. Unscrew the ceramic cartridge (45 882 - right close, 

45 883 - left close) using a 17mm (11/16") wrench.

II. Flow straightener, see fold-out page II.
Unscrew and clean flow regulator (13 934).

Assemble in reverse order.

Replacement parts, see fold-out page II  ( * = special 
accessories).

Care

Instructions for care of this faucet will be found in the 
Limited Warranty supplement.

940820.book  Seite 1  Montag, 17. Dezember 2001  2:49 14