6
Shut off cold and hot water supplies.
IV. Solenoid valve
1. Loosen screw (U1), see Fig. [10].
2. Unscrew screws (U).
3. Unscrew screw (W1) and decrease solenoid
valve (Z) with adapter (W), see Fig. [11].
4. Decrease plate (W2) and pull out solenoid valve (Z) from the
adapter (W).
5. Remove filter (Z1).
Re-assemble in reverse order.
It must be ensured that the interior of the housing is dry.
The solenoid valve (Z) must be turned when inserting into the
adapter (W) in a clockwise direction against the impact.
Make sure that the cartridge seals of the
adapter (W) engage in the grooves on the housing.
Fit screws (W1) and tighten
evenly and alternately
.
III. Thermostatic cartridge
1. Remove screw (N1) and pull off handle cap (N),
see Fig. [12].
2. Remove screw (O) and pull off scale handle (P).
3. Remove clip (X1).
4. Pull off stop ring (X).
5. Remove adjusting nut (S) with overload unit (S1).
6. With a 22mm open-ended spanner, unscrew and remove
thermoelement (Y).
Re-assemble in reverse order.
The overload unit (S1) (left-hand thread) must be screwed as
far as possible into the adjusting nut (S).
Observe the correct installation position of the stop
ring (X).
Re-adjustment is necessary after every maintenance
operation on the thermostatic cartridge (see Adjustment).
IV. Non-return valve,
see spare parts on fold-out
page I.
Screw out complete non-return valve (43 433) and take out
non-return valve (43 432).
Replacement parts,
see fold-out page I
( * = special accessories).
Care
For directions on the care of this mixer, please refer to the
accompanying Care Instructions.
Problem / Cause / Remedy
Problem
Cause
Remedy
Water does not flow
•
Battery without contact
•
Water supply interrupted
•
Filter before solenoid valve is
clogged
•
Solenoid valve defective
•
Mounting mode is active
•
Quantity of water too small
•
Battery empty
- Clean contacts, see maintenance cartridge
- Open stop valves
- Clean, see maintenance solenoid valve
- Replace, see maintenance solenoid valve
- Press operation cap twice (doubleclick)
- Examine hose transfer
- Replace, see maintenance cartridge
Pulsating water jet
•
Battery almost empty
- Replace, see maintenance cartridge
Water flows
continuously
•
Solenoid valve defective
- Replace, see maintenance solenoid valve
Quantity of water too
small
•
Water supply throttled
•
Filter for solenoid valve is clogged
•
Filter in non-return valve is clogged
- Open isolating valves, Check supply pipes
- Replace, see maintenance solenoid valve
- Replace, see maintenance check valve
Water temperature
too high or low
•
Thermostat not adjustet to local
pressure
•
Non-return valves defective
- Adjust thermostatic cartridge, see
adjustment
- Replace, see maintenance non-return valve
Summary of Contents for Eurodisc SE 36 247