background image

6

Shut off cold and hot water supplies.

IV. Solenoid valve

1. Loosen screw (U1), see Fig. [10].
2. Unscrew screws (U).
3. Unscrew screw (W1) and decrease solenoid 

valve (Z) with adapter (W), see Fig. [11].

4. Decrease plate (W2) and pull out solenoid valve (Z) from the 

adapter (W).

5. Remove filter (Z1).

Re-assemble in reverse order.

It must be ensured that the interior of the housing is dry.

The solenoid valve (Z) must be turned when inserting into the 
adapter (W) in a clockwise direction against the impact. 

Make sure that the cartridge seals of the 
adapter (W) engage in the grooves on the housing. 
Fit screws (W1) and tighten 

evenly and alternately

.

III. Thermostatic cartridge

1. Remove screw (N1) and pull off handle cap (N),

see Fig. [12].

2. Remove screw (O) and pull off scale handle (P).
3. Remove clip (X1).

4. Pull off stop ring (X).
5. Remove adjusting nut (S) with overload unit (S1).
6. With a 22mm open-ended spanner, unscrew and remove 

thermoelement (Y).

Re-assemble in reverse order.

The overload unit (S1) (left-hand thread) must be screwed as 
far as possible into the adjusting nut (S).

Observe the correct installation position of the stop 
ring (X).

Re-adjustment is necessary after every maintenance 
operation on the thermostatic cartridge (see Adjustment).

IV. Non-return valve,

 see spare parts on fold-out 

 page I.

Screw out complete non-return valve (43 433) and take out 
non-return valve (43 432).

Replacement parts, 

see fold-out page I 

( * = special accessories).

Care

For directions on the care of this mixer, please refer to the 
accompanying Care Instructions.

Problem / Cause / Remedy

Problem

Cause

Remedy

Water does not flow

Battery without contact

Water supply interrupted

Filter before solenoid valve is 
clogged

Solenoid valve defective

Mounting mode is active

Quantity of water too small

Battery empty

-  Clean contacts, see maintenance cartridge
-  Open stop valves
-  Clean, see maintenance solenoid valve

-  Replace, see maintenance solenoid valve
-  Press operation cap twice (doubleclick)
-  Examine hose transfer
-  Replace, see maintenance cartridge

Pulsating water jet

Battery almost empty

-  Replace, see maintenance cartridge

Water flows 
continuously

Solenoid valve defective

-  Replace, see maintenance solenoid valve

Quantity of water too 
small

Water supply throttled

Filter for solenoid valve is clogged 

Filter in non-return valve is clogged

-  Open isolating valves, Check supply pipes
-  Replace, see maintenance solenoid valve
-  Replace, see maintenance check valve

Water temperature 
too high or low

Thermostat not adjustet to local 
pressure

Non-return valves defective

-  Adjust thermostatic cartridge, see 
 adjustment
-  Replace, see maintenance non-return valve

Summary of Contents for Eurodisc SE 36 247

Page 1: ...O 19 LV 23 RUS 27 E 4 DK 8 UAE 12 P 16 HR 20 LT 24 Design Quality Engineering GROHE Germany Eurodisc SE Eurodisc SE 94 005 331 ÄM 218740 10 12 36 247 D 1 I 13 N 25 GR 37 TR 49 BG 61 RUS 73 GB 4 NL 16 FIN 28 CZ 40 SK 52 EST 64 RUS 26 F 7 S 19 PL 31 H 43 SLO 55 LV 67 E 10 DK 22 UAE 34 P 46 HR 58 LT 70 ...

Page 2: ...ease pass these instructions on to the end user of the fitting S v p remettre cette instruction à l utilisateur de la robinetterie Bitte diese Anleitung an den Benutzer der Armatur weitergeben 36 014 36 247 ...

Page 3: ...II 4 J1 H1 H K K1 J A C C1 C2 D 2 B A 1 3 G E C G C G1 5 1 2 3 2mm 30 C N 7 10 U1 U V 2 5mm W2 Z 11 W1 W Z1 1 2 2 5mm N O P R S T T1 9 T N1 2 5mm N O P R 8 N1 6 L O P X1 S1 Y 2 5mm 12 S 22mm X N N1 ...

Page 4: ... Dispose of batteries in accordance with national regulations Installation Plaster and tile the wall excluding the area occupied by the installation protection 1 Unscrew screws A and keep for mounting retaining cover see fold out page II Fig 1 2 Cut off rough installation protection B tile justified 3 Fasten retaining cover C with screws A C1 and washer C2 through the rough installation protection...

Page 5: ...crew N1 and pull off handle cap N 3 Remove screw O and pull off scale handle P Caution Adjusting nut S should not be adjusted 4 Pull off red end stop T and refit with the arrow T1 pointing to the maximum desired temperature 5 Push on scale handle P in such a way that the 20 C mark on the handle coincides with the mark R on the cover plate and fasten with screw O 6 Push on handle cap N and fasten w...

Page 6: ...see Adjustment IV Non return valve see spare parts on fold out page I Screw out complete non return valve 43 433 and take out non return valve 43 432 Replacement parts see fold out page I special accessories Care For directions on the care of this mixer please refer to the accompanying Care Instructions Problem Cause Remedy Problem Cause Remedy Water does not flow Battery without contact Water sup...

Page 7: ......