background image

10

Cleaning Recommendation for Hansgrohe Products

Modern faucetry and shower products utilize a combination of materials to comply with the needs of the 

market with regard to design and functionality.

To avoid damage, it is necessary to use some caution when cleaning. Damage caused by improper 

treatment is not covered under the Hansgrohe warranty.

Cleaning Materials for Faucets and Showers

 

To remove lime scale, use only products made specifically for that purpose.  Always follow the 

manufacturer’s instructions when using.

 

Do not use cleaners that contain hydrochloric, formic, acetic, or phosphoric acids, as these will 

cause considerable damage to finishes and to plastic components.

 

Never mix cleaning materials.

 

Never use cleaners containing abrasives.  Do not use abrasive cleaning cloths, pads, or sponges.

Cleaning Procedures

 

Clean your faucets and shower products as and when required.  Regular cleaning will prevent 

scale buildup and water spotting.

 

Follow the label instructions.  Do not allow any cleaner to remain on the product for longer than 

necessary.

 

When using spray cleaners, spray first onto a sponge or cloth – do not spray directly onto the 

product.

 

After cleaning, rinse thoroughly with clear water to remove any cleaner residue.

Important

 

Soap and shampoo residue can also cause damage to the product.  Rinse well with clean water 

after use.

 

If the surface is already damaged, harsh cleaning materials will cause further damage.

Summary of Contents for Electronic 15180XX1

Page 1: ...Electronic 15181XX1 Electronic 15180XX1 Installation Instructions Warranty ...

Page 2: ...mended hot water temperature 120 F 140 F Rate of flow 1 5 gpm 44 psi Automatic shutoff after 35 seconds Hole size in mounting surface 1 3 8 Max mounting surface thickness 1 1 8 Requires standard 110V electrical outlet please know and follow all applicable local plumbing codes when setting the temperature on the water heater In Massachusetts the water heater may be set no higher than 112o F please ...

Page 3: ...ce the faucet in the hole in the mounting surface 1 From beneath the sink install the fiber washer metal washer and mounting nut 2 Install the adapters on the stops 3 Install the filters 4 and supply lines 5 Connect the transformer Plug into the outlet Use a cable tie to bundle excess cable ...

Page 4: ...Wait 15 seconds then put a hand in front of the sensor The water should turn on automatically Model 15180 only Pivot the temperature control lever forward to make the water cooler Model 15181 only Turn the water off at the stops 1 Remove the set screw on the back of the faucet 2 ...

Page 5: ...ature 2 Turn the screw to the rear to make the water warmer to the front to make it cooler Replace the faucet housing Tighten the set screw Cleaning Block the sensor for 5 seconds 1 This will turn the water off for approximately 75 seconds so that the sink may be cleaned 2 ...

Page 6: ... Faucet Maintenance Reset the faucet Remove the set screw with a 2 5 mm Allen wrench Block the sensor for 2 seconds Wait 10 seconds 1 then replace the set screw 2 ...

Page 7: ...n Cleaning the filters and aerator If the flow of water is reduced the filters and or the aera tor must be cleaned To clean the aerator Block the sensor for 5 seconds to temporarily shut off the water 1 Unscrew and remove the aerator Flush any debris from the aerator at another faucet 2 ...

Page 8: ... To clean the filters Turn the water off at the stops 1 Disconnect the supply hoses from the adapters 2 Pull the filters out and clean them ...

Page 9: ...1 aerator 96788XXX 2 solenoid valve 98854000 3 fixation set 97812000 4 connection hose 96405000 5 back flow preventor cartridge 96906000 6 electronics 96905000 7 AC adapter 97690000 8 transformer 97689001 1 2 3 4 5 6 7 8 ...

Page 10: ...ill cause considerable damage to finishes and to plastic components Never mix cleaning materials Never use cleaners containing abrasives Do not use abrasive cleaning cloths pads or sponges Cleaning Procedures Clean your faucets and shower products as and when required Regular cleaning will prevent scale buildup and water spotting Follow the label instructions Do not allow any cleaner to remain on ...

Page 11: ...f you are a consumer who purchased the product for use primarily for personal family or household purposes this warranty extends for as long as you own the product and the home in which the product is originally installed If you purchased the product for use primarily for any other purpose including without limitation a commercial purpose this warranty extends only i for 1 year with respect to Han...

Page 12: ...HE NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO CREATE FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THIS PRODUCT HANSGROHE SHALL NOT BE LIABLE TO PURCHASER OR ANY PERSON FOR ANY INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY INCLUDING MERCHANTABILITY Some States do not allow the exclusion or limitation of incidental or consequent...