2
If the Blue
®
handle is flashing red and E4 or E6 appears in
the display, the fitting and control unit must be
synchronised as follows,
see Fig. [8]
:
• Press and hold the and
c
buttons simultaneously until
SE
flashes in the display.
• Press the button until
SE
stops flashing.
• Release the button,
C-
flashes in the display.
• Keep pressing the
U
or
c
button until
H-
flashes in the
display.
• Press the button until
H-
stops flashing.
• Blue
®
handle synchronisation starts;
HC
appears in the
display and the Blue
®
handle lights up
red
.
• As soon as the Blue
®
handle lights up
green
, open the fitting
fully by turning the Blue
®
handle.
• As soon as the Blue
®
handle briefly flashes
green
, close the
fitting by turning the Blue
®
handle,
HC
flashes in the display.
• Confirm the setting by pressing the button longer,
HC
appears.
• Release the button.
The remaining filter capacity is displayed.
Operation / Commissioning
Open
lever
in order to draw hot and cold tap water, see
fold-out page II, Fig. [9].
Open
Blue
®
handle
to draw off filtered GROHE Blue
®
water.
Control unit,
see fold-out page II, Fig. [8].
The buttons perform the following functions:
Filter replacement reset
U
Filter size selection
c
Carbonate hardness adjustment
Display,
see fold-out page II, Fig. [8].
In the inactive state, the remaining filter capacity is displayed
in percent.
Display of filter capacity in Blue
®
handle:
Set carbonate hardness at filter head,
see Fig. [10].
The relevant water supplier can provide information on the
carbonate hardness.
Set carbonate hardness at bypass setting of filter head to local
conditions, see table column
A
on fold-out page III.
Setting carbonate hardness on control unit,
see table
column
B
on fold-out page III and Fig. [8].
c
button for carbonate hardness adjustment:
• Press and hold the
c
button once until the currently setted
value (e. g. C3) flashes in the display
• Press the
c
button and select the required value:
- C4: carbonate hardness
≤
9
(bypass 3)
- Factory setting:
C3: carbonate hardness
10 - 24
(bypass 2)
- C2: carbonate hardness
25 - 29
(bypass1)
- C1: carbonate hardness
≥
30 (bypass
0)
• Press and hold the
c
button until the setted value stops
flashing
• Release the
c
button.
The remaining filter capacity is displayed.
The liter capacity of the cartridge varies according to the water
hardness set and the size of the cartridge, see table on fold-
out page III.
The control unit of the GROHE Blue
®
fitting is set for operation
with the 600 liter filter cartridge (Prod no.: 40 404 001) at the
factory.
For operation with other filter cartridges the control unit must be
set out.
Setting filter size,
see fold-out page II, Fig. [8].
U
button for filter size selection:
• Press and hold
U
button once until the currently setted
value (e. g. F1) flashes in the display
• Press the
U
button and select the required value appears
- F1:
600 liters
40 404 000
- F2:
1,500 liters
40 430 000
- F3:
3,000 liters
40 412 000
- F4:
600 liters
40 404 001
- F5:
1,500 liters
40 430 001
- F6:
3,000 liters
40 412 001
- F7:
600 liters
40 691 001 (Magnesium)
- F8:
3.000 liters
40 547 001 (Activ carbon)
• Press and hold the
U
button until the required value stops
flashing
• Release the
U
button:
The remaining filter capacity is displayed.
The fitting is now fully installed and ready for operation.
Note: The various filter cartridges
can be ordered at
www.grohe.com
.
Maintenance
Resetting filter capacity after changing filter cartridge,
see
fold-out page II, Fig. [8].
button for filter replacement reset:
• Press and hold button until
rF
flashes in the display.
• Release the button and press again until
rF
stops
flashing.
• Release the button.
The remaining filter capacity is reset and then displayed
again.
Flashing signal
Meaning
Filter capacity of more than 10%
Filter capacity of less than 10%
Order filter cartridge
Filter capacity of less than 1%
Change filter cartridge soon
No filter capacity
Change filter cartridge
immediately